6.2. Servicing protocol (RS-232)
The servicing protocol is used to retrieve and modify device operating parameters.
Various device settings, such as unit system and filtering parameters are configured using
this protocol. Since NMEA protocol is one way (it only outputs the data), the servicing
protocol is always active.
To make radar configuration easy, Geolux provides a Configurator utility
application. Regular users do not need to be concerned about the servicing protocol used
between the Configurator utility and the level meter device. The Configurator utility is
described in the Chapter 7 of this manual.
The servicing protocol listens on RS-232 serial port for incoming requests, and on
each received request, it will answer back.
The following requests are recognized by the servicing protocol:
Change serial number
#set_serial_number=<>
Sets the serial number, which is up to six printable ASCII characters.
Change serial baud rate
#set_baud_rate=9600
#set_baud_rate=38400
#set_baud_rate=57600
#set_baud_rate=115200
Changes the device serial baud rate.
Change modbus ID
#set_modbus_id=<1-255>
Changes the device modbus ID. Accepts integer values.
Change SDI-12 ID
#set_sdi_id=<1-255>
Changes the device SDI-12 ID. Accepts integer values.