User Guide
7 8
DOC CONTROL: HW-IS-0-0094 DOC REVISION: 200501a
Safety Regulatory Guidance Safety Regulatory Guidance
Conforms to:
IEC 62368-1:2018 (for ordinary locations safety)
EN 62368-1: 2018 (for ordinary locations safety)
ANSI / UL 62368-1: 2014 (for ordinary locations safety)
Certified to:
CAN / CSA C22.2 No. 62368-1-2014 (for ordinary locations safety)
Conforms To:
IEC 60079-0: 2011 (for hazardous locations safety
Ex Class I: Zone 0, Group IIC classification)
IEC 60079-11: 2011 (for hazardous locations safety
Ex Class I: Zone 0, Group IIC classification)
EN 60079-0: 2012 (for hazardous locations safety
Ex Class I: Zone 0, Group IIC classification)
EN 60079-11: 2012 (for hazardous locations safety
Ex Class I: Zone 0, Group IIC classification)
ANSI / UL 913: 2013 (for hazardous locations safety
Class I: Division 1, Groups A-D classification)
ANSI / UL 60079-0: 2013 (for hazardous locations safety
AEx Class I: Zone 0, Group IIC classification)
ANSI / UL 60079-11: 2013 (for hazardous locations safety
AEx Class I: Zone 0, Group IIC classification)
Certified To:
CAN / CSA C22.2 No. 157-92: R2016 (for hazardous locations safety
Class I: Division 1, Groups A-D classification)
CAN / CSA C22.2 No. 60079-0: 2011 (for hazardous locations safety
Ex Class I: Zone 0, Group IIC classification)
CAN / CSA C22.2 No. 60079-11: 2014 (for hazardous locations safety
Ex Class I: Zone 0, Group IIC classification)
All Geoforce GT2 products are conformant, recognized and certified in a varienty of
industrial operating environments including ordinary locations.
ORDINARY LOCATIONS SAFETY (FUTURE)
HAZARDOUS LOCATIONS SAFETY (FUTURE)
GT2c
GT2C-SL-EX
GT2s
GT2S-IRD-SL-EX
GT2h
GT2H-IRD-SL-EX
In addition to Ordinary Locations operations, the following GT2 model codes are conformant,
recoginzed, and certified for full time opeartion in classified Hazardous Locations:
These device models are certified Intrinsically Safe for operation in Class I: Division 1,
Class I: Division 2, and Zone 0, 1 and 2 environments for all Gas Groups.
HAZARDOUS LOCATIONS MARKINGS APPLIED (FUTURE)
IECEX/INMETRO
Ex ia IIC T4 Ga
-40°C < T
amb
< +75°C IP68
IECEX CERTIFICATE NUMBER:
INMETRO CERTIFICATE NUMBER:
ETL NN.NNNNX
NCC NN.NNNNX
EU (ATEX)
NNNN II 1 G Ex ia IIC T4 Ga
-40°C < T
amb
< +75°C IP68 ATEX CERTIFICATE NUMBER: ITSNNATEXNNNNNX
USA/CANADA
Class I: Division 1 | Groups A-D T4
US: Class I: Zone 0 | AEx ia IIC T4 Ga
CAN: Class I: Zone 0 | Ex ia IIC T4 Ga
-40°C < T
amb
< +75°C
IP68
US/CANADA LISTING NUMBER: NNNNNNN
Ex:
Explosion Protection “Ex” for equipment certified for Hazardous Locations
Equipment Group:
“II” for non-mining applications
Equipment Category:
“1” for equipment suitable for Gas, Vapor, Mist and Dust Environments
Protection Method:
“ia” for Intrinsic Safety with two fault protection
Gas Group:
“IIC” for all Gas Groups (IIA, IIB and IIC)
Temperature Classification:
“T4”
Equipment Protection Level:
“Ga” Very high protection suitable for Zone 0,1, and 2 Gas Environments
Ambient Temperature Range:
“-40°C < T
amb
< +75°C” The device is approved for EX operation within this temperature range.
MARKINGS SENTENCES BREAKDOWN (FUTURE)
INTRINSICALLY SAFE