Installation Instructions

THEORETICAL YIELD
per 10.3 fl. oz. cartridge
Joint Size Linear Feet
1/4” x 1/4” 24.8
1/4” x 3/8” 16.5
1/4” x 1/2” 12.4
1/2” x 3/8” 8.7
1/2” x 1/2” 6.2
3/4” x 1/2” 4.1
7. MAINTENANCE:
No maintenance should be required.
If the sealant is damaged, either
remove bead and reseal with Ultima
or apply additional Ultima over the
damaged area.
Geocel Products Group
representatives throughout the United
States are available to provide
technical assistance. Geocel
Products Group’s in-house technical
staff and laboratory facilities are
equipped to respond to specific
requests for further information.
and/or applications testing.
8. TECHNICAL SERVICES:
6. LIMITED WARRANTY:
5. AVAILABILITY AND COST:
Available from various lumber
yards, hardware stores, and home
centers. Costs and further
technical data are available from
your local Geocel Products Group
representative or from our office.
(lacquer thinner) to clean joints or
to remove surface coatings, unless
surface can be allowed to dry
before application of sealant. If the
joint is wet with solvent, the
sealant will not adhere properly.
Use of a dry rag or brush to
remove dust, dirt, or other
contaminants is recommended.
Contamination from curing agents
and form releases should be
avoided. Contact Geocel Products
Group's Technical Service
Department or representative if
such agents are involved.
Elongation: 1062% - Crystal Clear
1180% - Colors
Tack Free: 45 minutes
Cure: 4 days
Joint Backing: Joint depth should
not exceed 3/8". An open cell
backer rod should be used to
control joint depth. In shallow
joints, a bond breaker tape should
be installed to prevent three-point
contact.
Application and Tooling: Apply
with conventional caulking
equipment, filling joint completely.
When temperature is below 40° F
(4° C), application will be easier if
sealant is warmed. When
temperature of surface to be
sealed exceeds 140° F (60° C), do
not apply sealant until surface
cools. A soap solution or a solvent
such as Xylol may be used as a
lubricant for tooling. Do not allow
tooling agents to contaminate
open joints.
Painting:Ultima Sealant may be
painted after 24 hours. If using a
relatively inflexible paint, allow
sealant to cure for 3 days before
painting. Ultima Sealant may be
coated with any latex and most
oil-based paints. Some paints may
crack in dynamic joints. See paint
manufacturer's specifications.
Cleaning: Remove Ultima
Sealant from gun and tools
before it cures. This may be
done by scraping and use of
solvents such as MEK (lacquer
thinner), xylene, Toluol, or
chlorinated solvents. Cured
materials may be removed by
cutting with sharp tools. Observe
manufacturer's precautions when
using toxic or flammable solvents.
Storage Life: One year
Cautions: Contains AROMATIC
HYDROCARBONS. Contents are
COMBUSTIBLE. Keep away from
heat and open flame. VAPOR
HARMFUL. Use only with
adequate ventilation. To avoid
overexposure, open windows and
doors or use other means to
ensure fresh air entry during
application and drying. If you
experience eye watering,
headaches, or dizziness, increase
fresh air, or wear respiratory
protection (NIOSH approved) or
leave the area. Avoid contact with
eyes and skin. Wash hands after
using. Keep container closed
when not in use. Do not transfer
contents to other containers for
storage.
First Aid: In case of eye contact,
flush thoroughly with large
amounts of water for 15 minutes
and get medical attention. For
skin contact, wash thoroughly
with soap and water. In case of
respiratory difficulty, provide fresh
air and call physician. If
swallowed, call Poison Control
Center, hospital emergency room,
or physician immediately.
DELAYED EFFECTS FROM LONG
TERM OVEREXPOSURE.
Contains solvents which can
cause permanent brain and
nervous system damage.
Intentional misuse by deliberately
concentrating and inhaling the
contents can be harmful or fatal.
Warning: This product contains
chemicals known to the State of
California to cause cancer and
birth defects or other reproductive
harm. DO NOT TAKE
INTERNALLY. KEEP OUT OF THE
REACH OF CHILDREN.
©2015 Geocel Products Group
A Business Unit of The Sherwin-Williams Company
701272 1115
REGISTERED
O
9001
14001
Setting the Standard
®
Cleveland, OH 44115
(800) 348-7615
Fax (800) 348-7009
www.GeocelUSA.com
If when applied according to label
directions this product fails to perform
in accordance with its published
literature, upon satisfactory evidence
of product failure, and as your sole
remedy, we will either replace the
product at no cost or refund the
original purchase price for that portion
of product that fails to perform in
accordance with this limited warranty.
Labor or costs associated with labor
are not included. THIS LIMITED
WARRANTY IS IN LIEU OF ALL
OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING
MERCHANTABILITY, WHICH ARE ALL
DISCLAIMED AND/OR LIMITED IN
DURATION TO THE EXTENT
PERMITTED BY LAW. WE SHALL
NOT BE LIABLE FOR INDIRECT,
SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES
(INCLUDING LOST PROFITS) FROM
ANY CAUSE WHATSOEVER AND
SUCH DAMAGES ARE EXPRESSLY
EXCLUDED. Some states do not
allow the exclusion or limitation of
incidental or consequential damages
or how long an implied warranty lasts,
so the above limitation or exclusion
may not apply to you. This limited
warranty gives you specific legal
rights, and you may also have other
rights which vary from state to state.