Product Manual
Part No. 145358 Genie IWP Super Series 19
Operator’s ManualFifth Edition • Third Printing
OPERATING INSTRUCTIONS
Emergency Stop
1 Push in the red Emergency Stop button at the
platform controls or at the ground controls to
stop the up function.
Platform Raise and Lower
1 Pull out the red Emergency Stop button at the
platform controls to the on position.
2 Push in the control activate button and rotate
the up/down switch in the desired direction of
travel.
Manual Lowering
1 Activate the manual
lowering valve located at
the bottom of the
hydraulic cylinder.
Auxiliary Platform Lowering
1 Turn the key switch to ground control.
2 Activate the auxiliary platform lowering button at
the ground controls.
Fall Protection
Personal fall protection equipment (PFPE) is not
required when operating this machine. If PFPE is
required by job site or employer rules, the following
shall apply:
All PFPE must comply with applicable
governmental regulations and must be inspected
and used in accordance with the manufacturer’s
instructions.
After Each Use
1 Select a safe storage location—firm, level
surface, weather protected, clear of
obstructions and traffic.
2 Pull the base lowering handle to lower the base
until all four footpads are in firm contact with the
ground.
3 Remove the key to secure from unauthorized
use.
4 DC models: Recharge the battery.
8 Be sure that the two level sensor interlock
display lights and the two footpad interlock
display lights are on.
Note: Two different interlock display decals were
produced. The symbols on them are different but
they both operate the same way. Both are
illustrated in this text.