Product Manual
Part No. 145358 Genie IWP Super Series 15
Operator’s ManualFifth Edition • Third Printing
10 Pull the base lowering handle to lower the base.
Result: The two footpad display lights should be
on.
11 Pump the foot pedal to raise the base.
12 Turn both the leveling jacks clockwise to the full
down position.
13 Pull the base lowering handle to lower the base.
Result: The base will lower and the two level
sensor display lights should be off and remain
off because the base is not level.
14 At the platform controls, push in the control
activate button and rotate the up/down switch to
the up position, then the down position.
Result: The platform up/down function should
not operate.
Test Emergency Stop
15 Use the bubble level and adjust the leveling
jacks until the machine base is level. Be sure all
four display lights at the ground controls are on.
16 Push in the red Emergency Stop button at the
ground controls.
17 At the platform controls, push in the control
activate button and rotate the up/down switch in
each direction.
Result: The platform up/down function should
not operate.
18 Push in the red Emergency Stop button at the
platform controls and pull out the red
Emergency Stop button at the ground controls.
19 At the platform controls, push in the control
activate button and rotate the up/down switch in
each direction.
Result: The platform up/down function should
not operate.