Product Manual
14 Genie IWP Super Series Part No. 145358
Operator’s Manual Fifth Edition • Third Printing
8 Pull out the red Emergency Stop button at the
platform controls to the on position.
Result: The power light should come on. Within
1 to 4 seconds, the two level sensor interlock
display lights and the two foot pad interlock
display lights should turn on and remain on.
Note: Two different interlock display decals were
produced. The symbols on them are different but
they both operate the same way. Both are
illustrated in this text.
Test Interlock System
9 Pump the foot pedal to raise the base.
Result: The two footpad display lights should be
off.
FUNCTION TESTS
Function Tests
1 Select a firm, level test area free of
obstructions.
2 Pump the foot pedal to
raise the base.
Result: The wheels
should contact the
ground.
3 Pull the base lowering
handle to fully lower
the base.
Result: All four foot
pads should come in
firm contact with the ground.
4 Connect the appropriate power source.
5 Use the bubble level and adjust the leveling
jacks until the machine is level and all four foot
pads are in firm contact with the ground.
6 Insert the key and turn to platform control.
7 Pull out the red Emergency Stop button at the
ground controls to the on position.