Product Manual

Sixth Edition • Fourth Printing Operator's Manual
Work Area Safety
Part No. T107026 GS-30 • GS-32 • GS-46 11
Work Area Safety
Electrocution Hazards
This machine is not electrically insulated and will
not provide protection from contact with or
proximity to electrical current.
Obey all local and
governmental
regulations regarding
required clearance from
electrical power lines. At
a minimum, the required
clearance contained in
the chart below must be
followed.
Line Voltage Required Clearance
0 to 50KV 10 ft 3.05 m
50 to 200KV 15 ft 4.60 m
200 to 350KV 20 ft 6.10 m
350 to 500KV 25 ft 7.62 m
500 to 750KV 35 ft 10.67 m
750 to 1000KV 45 ft 13.72 m
Allow for platform movement, electrical line sway or
sag, and beware of strong or gusty winds.
Keep away from the
machine if it contacts
energized power lines.
Personnel on the ground
or in the platform must
not touch or operate the
machine until energized
power lines are shut off.
Do not operate the machine during lightning or
storms.
Do not use the machine as a ground for welding.
Tip-over Hazards
Occupants, equipment and materials shall not
exceed the maximum platform capacity or the
maximum platform capacity of the platform
extension.
Maximum capacity
Platform extended
Model
Platform
retracted
Platform
only
Extension
only
Maximum
occupants
GS-1530
600 lbs
272 kg
350 lbs
159 kg
250 lbs
113 kg
2
GS-1930
500 lbs
227 kg
250 lbs
113 kg
250 lbs
113 kg
2
GS-2032
800 lbs
363 kg
550 lbs
249 kg
250 lbs
113 kg
2
GS-2632
500 lbs
227 kg
250 lbs
113 kg
250 lbs
113 kg
2
GS-3232
500 lbs
227 kg
250 lbs
113 kg
250 lbs
113 kg
2
GS-2046
1200 lbs
544 kg
950 lbs
431 kg
250 lbs
113 kg
2
GS-2646
1000 lbs
454 kg
750 lbs
340 kg
250 lbs
113 kg
2
GS-3246
700 lbs
318 kg
450 lbs
204 kg
250 lbs
113 kg
2
Platform retracted Platform extended
Extension only Platform only