Owner's Manual
CONTROL SIGNAL TERMINAL STRIP
EXT
NTLK
EXT
NTLK
NOTE: If External Interlock is used, THE JUMPER WIRE BETWEEN THE
EXT INTLK TERMINALS MUST BE REMOVED.
1) Optional external interlock switches are
required with some Sectional or Rolling Steel
Doors to prevent the door from operating
under certain conditions including
the following:
• If the door is equipped with a
functioning door lock, an interlock
switch (A) must be installed to prevent
electric operation when the lock
is engaged.
• If the door is equipped with a pedestrian
pass-through door, an interlock switch (B)
must be installed at the pass-through
door in order to prevent electrical
operation when the pass-through door
is open.
2) The Switches must be set in the field.
SWITCH
075412-0000.S
(N.O.)
ANGLE
405964-0000.S
STANDARD
SLIDELOCK
TRACK
SWITCH (N.C.) P/N 110324.0001.S
For Sectional Door
Left-hand P/N 110325.0001.S
For Rolling Steel Door
Interlock Switches (Wall Mount)
5.5
A
B
Pass door interlock:
Should be open when
door is open.
Closed when door
is closed.
Side lock interlock:
Should be engaged when door is locked.
Disengaged when door is unlocked.
Figure 6
www.geniecompany.com 06-12
Standard Duty Operator
GCL-T