Owner's Manual
5.1
www.geniecompany.com 06-12
WARNING
• DO NOT apply power to operator until instructed to do so.
• The Genie® Company recommends that line voltage wiring
be performed by a qualified electrician.
• Be sure that electrical power has been disconnected from the
input power wires being connected to the operator prior to
handling these wires. An appropriate lock-out /tag-out procedure
is recommended.
• Line voltage wiring must meet all local building codes.
• Make sure operator voltage, phase and frequency nameplate
ratings are identical to the job site line voltage ratings.
• Input power wiring must be properly sized for the operators
amperage rating located on the nameplate.
• To reduce the risk of electric shock, make sure the chassis of this
unit is properly grounded.
1) Remove LINE VOLTAGE INPUT PLUG and install proper
fittings and 1/2”conduit.
2) Route proper LINE VOLTAGE wires into operator.
3) Locate LINE INPUT terminals on circuit board. Using
correct connectors, attach wires to LINE INPUTS, and GROUND
terminal.
• Keep low
voltage and line voltage wires separate.
• Route all line voltage wires as shown.
• Plug all unused conduit holes.
P
HIGH
VOLTAGE
INPUT PLUGS
(Right & Left)
ROUTE HIGH VOLTAGE WIRING
IN THE SHADED AREA AS SHOWN
LINE INPUT
TERMINALS
LINE
GROUND
LINE INPUT
TERMINALS
LINE
GROUND
ROUTE HIGH VOLTAGE WIRING
IN THE SHADED AREA AS SHOWN
N/ 2
GND
LINE IN
POWER CONNECTIONS
LINE IN
POWER CONNECTIONS
LINE
(HO
NEU RAL
LINE
LINE 2
1
2
GND
LINE 1
LINE 2 L NE 3
Three Phase
Single Phase
5V
208V
230V
HIGH
VOLTAGE
INPUT PLUGS
(Right & Left)
Section 5: Wiring
Figure 1
Line Voltage Wiring Fig. 1
Standard Duty Operator
GCL-T