Owner's Manual

Medium Duty Operator
GCL-MT
www.geniecompany.com 08-12
6.1
The operators include a full function control panel including a liquid crystal
display (LCD), calibration keys and Open, Close and Stop keys for on board
operator control.See Fig.1. The open, close and stop keys function as a 3-button
wall control. The Display will show current operator conditions and calibration
information. Due to limited character space, some displays
will be abbreviated.
See Appendix C (pgs.10.11-10.13) for full display descriptions.
The operators also include a non-volatile memory. The unit will remember all
Make sure door is in the mid-travel position.
Apply
primary power.
calibration settings plus error code and run code logs, if power is removed
from unit.
NOTE: During Setup, refer to Caution Label for limited use (see page 5.4).
DANGER
: After power is supplied to the operator,
Control Operating Modes
APPLY POWER NOW
Operator control boards operate in two modes:Run Mode and Calibration
Mode.The control board should normally operate in the Run Mode.The operator
is calibrated in Calibration Mode.
With the opera
tor standing idle
PRESS CAL/RUN TO TOGGLE BETWEEN OPERATING MODES.
>
***”
(*** = current operating mode).
NOTE:The CAL/RUN key will not toggle between operator modes while
the operator is running.
Section 6: Operator Setup Procedure
Control Panel
LCD DISPLAY
Figure 1
Calibration &
Run Mode
Toggle Key.
Display
Backlighting
Toggle Key.
Scroll Keys, used in
Calibration Mode.
Set/Clear Key,
used to reset
and adjust
calibration
settings.
Operation Keys,
operates unit
like a 3-button
wall station.
Do Not make contact with components inside the control panel
except for the Keypad Keys. Fig. 1.
CAL
RUN
SET
SCROLL
SCROLL
CLEAR
OPEN
STOP
CLOSE