Owner's Manual

Medium Duty Operator
GCL-MT
www.geniecompany.com 0 -12
5.6
Radio Control and Photocell Wiring
RADIO
F
igure
8
Radio Control Installation
nwohs sa snoitcennoc ekam,noitallatsni lortnoc oidar eriw-3 a roF)1
in Fig. 8.
NOTE: PWR terminal supplies 20 40VDC. Radios used must be
compatible with this voltage range.
NOTE: If no voltage is present at PWR terminal, check fuse F1 on control board.
1) Monitored SERIES II (STB) photocells (P/N
OPAKPE.S or OPAKPEN4GX.S) and
Fig.
9.
Wiring
to these photocells can be connected to either terminal (they are
not polarity
sensitive). ( Troubleshooting in Section 8).
NOTE: Monitored Sensing device must be installed or unit will be Constant Contact Close.
2) To Mount Photocells: (Kit includes detailed Instructions).
Determine location for mounting. They do not need to be directly adjacent to the door but
.meht neewteb enil detcurtsbonu na si ereht os llaw eht no eb tsum
Fig
10.
Screws provided for mounting on soft material (wood, drywall, etc.).
They must extend out
away from the wall sufficiently that no door hardware
breaks the plane of the photo-beam.
1) Nominal 24 Volt DC Commercial photocells with normally open contacts can be
connected as shown in Fig. 11.
NOTE:
Blue wire supplies 20 – 40VDC. Photocells used must be compatible with this voltage range.
NOTE If no voltage is present at Blue wire, check fuse F-1 on Control board.
Series
II
Safe-T-Bea
Monitored Photocells
Commercial Non-Monitored Photocells
WARNING:
Photocell systems provide entrapment protection
when mounted near the doorway in such a way that the lower portion of an individual’s
leg will break the photocell beam during normal walking conditions.
WARNING:
Actuating operator using constant contact on
the CLOSE button will override external reversing devices, including photocells.
CONTROL SIGNAL
TERMINAL STRIP
Figure 9
CONNECT WIRES TO EITHER TERMINAL.
(NOT POLARITY SENSITIVE
)
+
-
+
-
CONTROL SIGNAL
TERMINAL STRIP
RADIO
Blue
Orange
Yellow
Figure
11
DOOR
Top of lens
to floor.
01 erugiF
Safe-T-Beam® Monitored Photocells from Genie® (P/N 38176R).
PWR
RAD GND
RELAY
GND
NOM
+24VDC
PWR
20-40 VDC @ 315 mA
MAX CURRENT
EXTERNAL RADIO TERMINAL STRIP
CLASS 2 SUPPLY 0-40 VDC
LOCATED
OUTSIDE
ELECTRIC
BOX
SERIES RESIDENTIAL
SAFE-T-BEAMS (STB)
ODC
STB
ODC
STB
N-O
REVERSE
N-O
REVERSE
THRU-BEAM
PHOTOCELLS
RECEIVER
TRANSMITTER
EXT RADIO CONNECTOR
PWR
20 0 VDC @ 3 5 mA
MAX CURREN
RELAY
GND
NOM
2 VDC
8