Owner's Manual
7.2
These operators are available for use in jackshaft or trolley configurations.
The same control board is used for either configuration, however the con-
trol board must be set for the appropriate GDO configuration. A board set
for trolley mode will not work in a jackshaft operator and vice-versa.
NOTE: The GDO type is factory set. The installer should not have to set
this f
eature. However, if the GDO type is inadvertently changed, or if a
board needs to be replaced in the field, follow these instructions to set
GDO type.
1) Press CAL/RUN to enter calibration mode.
2) Press SCROLL ( ) or ( ) until display reads “GDO TYPE
>
.”
This will display the current GDO t
ype.
3) Press SET/CLEAR until display indicates
correct GDO type
( J-SHAFT or TROLLEY)
4) Press CAL/RUN to return to run mode.
Operator Type Fig. 3
GDO TYPE J-SHAFT
Figure 3
www.geniecompany.com 08-12
Medium Duty Operator
GCL-MJ&MH