Owner's Manual
6.2
Setting Constant Contact
IDLE DOWN LIMIT
OPEN MODE C-STP
CLOSE MODE MOM
Figure 2
Figure 3
Figure 4
Door closed -
operator
standing by
CLOSE MODE C-STP
Figure 5
These operators are shipped from the factory with both open and close
operating modes set to constant contact – stop (C – STP) If your unit is set
to Momentary Contact (MOM) Open and/or CLOSE, reset the
operating modes by taking the following steps:
1) Press CAL/RUN to enter calibration mode. Fig. 2.
2)
Press SET/CLEAR until display reads “OPEN MODE
>
C-STP.” Fig. 3.
3) Press SCROLL (DN) until display reads “CLOSE MODE.” Fig. 4.
4) Press SET/CLEAR until display reads “CLOSE MODE
>
C-STP.”
Fig. 5.
5) P
ress CAL/RUN to return to run mode.
WARNING:
If a monitored external reversing device
is not used, then the operator will run Constant Contact Close.
Verify close mode is set to “C-STP”and NOT “C-REV”or “MOM”
before continuing.
www.geniecompany.com 08-12
Medium Duty Operator
GCL-MJ&MH