Owner's Manual
5.2
1) Connect all LOW VOLTAGE control circuit wires to this side
of unit using 1/2" conduit or flexible convoluted tubing.
Keep low voltage and line voltage wires separate.
Route all low voltage control wiring as shown. This includes
all control circuit wires such as wall controls, timers and single
button input devices as well as radio control and safety circuit
wiring. See Figs 2 through 13 in this section.
Plug all unused conduit holes.
Low Voltage Control Wiring (general) Fig. 3
NOTE: For a detailed description of control wire terminals see
Appendix B.
% G%
G C P
GH% OH % O
C
GP
C
GP
%U
N
U
N
RADIO
CONTROL
TERMINALS
LOW VOLTAGE
CONTROL WIRE
TERMINALS
LOW
VOLTAGE
INPUT
PLUGS
ROUTE LOW VOLTAGE
WIRING IN SHADED
AREA AS SHOWN
Figure 3
www.geniecompany.com 08-12
Medium Duty Operator
GCL-MJ&MH