Owner's Manual

WARNING:
SCROLL
2) Press SCROLL (up or down) until display reads “ODC STB>ON” or
6.5
OPEN
CLOSE
STOP
CAL
RUN
SCROLL
SCROLL
SET
CLEAR
ODC STB ON
NOTE: Installation of Series II Monitored Photocells DOES NOT make the operator
unit legal for residential use.
Monitored Reversing Devices
CAL
RUN
SET
CLEAR
SCROLL
CAL
RUN
ODC Safe-T-Beams® (OPTIONAL)
1) If operator is in RUN mode, press CAL/RUN to enter calibration mode.
“ODC STB>OFF” Figure 9.
3) Press SET/CLEAR key to toggle between ON and OFF.
4) Press SCROLL (up or down)
to shift to a new function and lock setting.
5) Press CAL/RUN to return to run mode.
Photocell systems provide entrapment
protection when mounted near the doorway in such a way
that the lower portion of an individuals leg will break the
photocell beam during normal walking through the doorway.
If an alternative mounting location is chosen, it must be
approved by the facility owner.
Current UL Approved Monitored Reversing Devices (See page 5.7)
1) MillerEdge ME and MT series monitored edge sensors used in
combination with Timer-Close Module P/N OPABTCX.S or OPAKMEIX.S INTERFACE MODULE.
2) MillerEdge ME and MT series monitored edge sensors (Direct connect through STB inputs).
(Direct connect through STB inputs).
3) Residential Safe-T-Beam® Monitored Photocells from The Genie® Company,
model OSTB-BX (P/N 38176R).
4) Monitored Photocells (P/N OPAKPEN4GX.S.).
Figure 9
www.geniecompany.com 08-12
Medium Duty Operator
GCL-MJ&MH