Owner's Manual

Wall Control(s) must be located so that the door is within
sight of the user and far enough from the door, or positioned,
such that the user is prevented from coming in contact with
the door while operating the controls.
Control. Fig. 4A
.
Attach the Caution label adjacent to the Wall Con Fig. 4B.
1) For one 3 - button installation, make connections as
shown in Fig. 4.
2) For a multiple 3 - button installations, make connections as
shown in Fig. 5.
3)
For single button accessory controls, make connections as
shown in Fig. 6.
NOTE: If an External STOP button is NOT being installed, a jumper
wire must b
e installed between the "STOP" AND "GND" terminals
as
shown in Fig. 6.
NOTE: Long Distance Relay K
it wiring is not required for long
distanc
e control runs and should not be used
Wall Control
Figure 4
Figure 5
Figure 6
WARNING:
Attach the Warning placard adjacent to the Wall
trol.
Entrapment
Warning
Placard
Figure 4A
CAUTION
This door is operated by a limited-duty operator.
To prevent the motor protector from tripping,
do not exceed 15 cycles of opening
and closing per hour.
NOT FOR RESIDENTIAL USE
Figure 4B
WARNING:
If momentary contact control is to be used, a monitored
switch must be used. See pages 5.6-5.7 for installation of entrapment
protection devices.
external reversing device such as a photocell system or sensing edge
11 735
5.4
www.geniecompany.com 08-12
Medium Duty Operator
GCL-MJ&MH