Owner's Manual

8.5
www.geniecompany.com 03-12
ON
NORMAL OPERATION
NONE REQUIRED
OFF
1. POWER HEAD NOT POWERED
2. WIRING FROM POWER HEAD BAD
1. CHECK BREAKERS, FUSES, PLUGS
2. CHECK WIRING FOR OBVIOUS SHORTS
ON
1. WIRING TO SOURCE MISSING OR BAD
2. POWER HAS BEEN INTERRUPTED
1. CHECK WIRING
2. REMOVE POWER AND REAPPLY
ON
1. BEAM NOT ALIGNED
2. BEAM OBSTRUCTED
3. SENSOR DEFECTIVE
1. CHECK ALIGNMENT
2. CHECK FOR OBSTRUCTION
3. CALL CUSTOMER SERVICE
1. WIRE TO SENSOR MISSING OR BAD
2. SENSOR DEFECTIVE
1. CHECK WIRING
2. CALL CUSTOMER SERVICE
OFF
ON
1. SENSOR RECEIVING INTERFERENCE
1.
ATTEMPT TO DETERMINE SOURCE OF
INTERFERENCE
2. CALL CUSTOMER SERVICE
ON
1. SOURCE NOT SENDING PULSES
2. SOURCE DEFECTIVE
1. CALL CUSTOMER SERVICE
2. CALL CUSTOMER SERVICE
SENSOR
(
GREEN LED
)
INDICATED CONDITION
REQUIRED ACTION
Safe-T-Beam® Monitored Photocell Self-diagnostic Troubleshooting Chart
ON
OFF
OFF
2 BLINKS, PAUSE
(REPEAT)
SOURCE
(
RED LED
)
2 BLINKS, PAUSE
(REPEAT)
3 BLINKS, PAUSE
(REPEAT)
4 BLINKS, PAUSE
(REPEAT)
WARNING:
THE GENI COMPANY
RECOMMENDS THAT LINE VOLTAGE WIRING BE PERFORMED
BY A QUALIFIED ELECTRICIAN. SEE SECTION 5 FOR
ADDITIONAL WIRING INSTRUCTIONS.
WARNING:
ACTUATING THE OPERATOR BY
USING CONSTANT CONTACT ON THE CLOSE BUTTON
WILL OVERRIDE EXTERNAL REVERSING DEVICES,
INCLUDING PHOTOCELLS.
Heavy Duty Operator
GCL-GT