NOTE: Installation of Series II Monitored Photocells DOES NOT make the GT™
unit legal for residential use. The Genie® Company strictly prohibits any
installation of a commercial unit in any residentially zoned construction.
Monitored Reversing Devices
CAL
RUN
CAL
SET
CLEAR
SCROLL
CAL
RUN
CAL
CROL
Safe-T-Beams® (OPTIONAL)
1) If operator is in RUN mode, press CAL/RUN to enter calibration mode.
2) Press SCROLL (up or down) until display reads “ODC STB>ON” or
“ODC STB>OFF” Figure 15.
3) Press SET/CLEAR key to toggle between ON and OFF.
4) Press SCROLL (up or down)
to shift to a new function and lock setting.
5) Press CAL/RUN to return to run mode.
WARNING: Photocell systems provide
entrapment protection when mounted near the doorway
in such a way that the lower portion of an individuals leg
will break the photocell beam during normal walking
through the doorway. If an alternative mounting location
is chosen, it must be approved by the facility owner.
Heavy Duty Operator
GCL-GT
Current UL Approved Monitored Reversing Devices
1) MillerEdge ME and MT series monitored edge sensors used in
combination with Timer-Close Module P/N OPABTCX.S.
2) MillerEdge ME and MT series monitored edge sensors used in
combination with MillerEdge Signature Module SM-101. (Direct
connect through STB inputs).
combination with MillerEdge Signature Module SM-101. (Direct
connect through STB inputs).
3) FRABA OptoEdge OSE-S-5010 series monitored edge sensors used in
combination with Timer-Close Module P/N OPABTCX.S.
4) FRABA OptoEdge OSE-S-5010 series monitored edge sensors used in
7) FRABA OptoEye OSE-S-5000, Monitored Photocells P/N OPAKPEN4.S and OPAKPEN4GX.S.
5) Residential Safe-T-Beam® Monitored Photocells from The Genie® Company,
model OSTB-BX (P/N 37221R).
6) Series II Safe-T-Beam® Monitored Photocells (P/N 37221R and OPAKPE.S).