Setting Open and Close Modes
(Constant vs Momentary Contact)
OPEN MODE MOM
Figure 10
NOTE: Momentary contact (MOM) or Constant Reverse (C-REV) may not be used
unless both the OPEN and CLOSE Limits have been set.
In situations where an external reversing device is either not installed or not
operating properly, Constant Contact (C-STP) MUST BE USED.
NOTE: During adjustment of a Travel Limit, the Open and Close Modes will
automatically fail-safe to Constant Contact until the Limit has been set or reset. At
that time the Open and Close Modes will revert to their previous setting.
CAL
RUN
SCROLL
OPEN
CLOSE
RU
SET
CLEAR
SCROLL
CAL
RUN
CAL
RUN
SCROLL
OPEN
CLOSE
RU
SET
CLEAR
CAL
RUN
SCROLL
WARNING: Before momentary contact
control can be used, an external reversing device such as
a photocell system or sensing edge switch must be used.
See pages 5.6-5.7 for installation of entrapment
protection devices.
OPEN
1) If operator is in RUN mode, press CAL/RUN to enter calibration mode.
2) Press SCROLL until display reads “OPEN MODE>MOM” or
“OPEN MODE>C-STP.”Figure 10.
MOM=momentary contact, meaning you press and release the
OPEN or CLOSE key and the door will continue to move
until it reaches its travel limit. (See NOTE)
C-STP=constant contact-stop, meaning if you release the key prior
to the door reaching its travel limit, the door will stop.
3) Press SET/CLEAR key to toggle between “OPEN MODE>C-STP” or
“OPEN MODE>MOM” on the display.
4) Press a SCROLL key to shift to a new function and lock in the setting.
5) Press CAL/RUN to return to run mode.
CLOSE
1) If operator is in RUN mode, press CAL/RUN to enter calibration mode.
2) Press SCROLL until display reads “CLOSE MODE>MOM,”
“CLOSE MODE>C-STP” or “CLOSE MODE>C-REV.” Figure 10.
MOM=momentary contact, meaning you press and release the
OPEN or CLOSE key and the door will continue to move
until it reaches its travel limit. (See NOTE)
C-STP=constant contact-stop, meaning if you release the key prior
to the door reaching its travel limit, the
door will stop.
C-REV=constant contact-reverse, meaning if you release the key
prior to the door reaching its travel limit, the door will
reverse direction. (See NOTE)
3) Press SET/CLEAR key to toggle between “CLOSE MODE>C-STP” or
“CLOSE MODE>C-REV” or ”CLOSE MODE>MOM” on the display.
4) Press a SCROLL key to shift to a new function and lock in the setting.
5) Press CAL/RUN to return to run mode.