Owner's Manual
5.4
www.geniecompany.com 03-12
1) For a single 3 - button installation, make connections as
shown in Fig. 3.
2) For single button accessory controls, make connections as
shown in Fig. 4.
3) For a multiple 3 - button installations, make connections as
shown in Fig. 5.
NOTE: If an External STOP button is NOT being installed, a jumper wire must
be installed between the “STOP” AND “GND” terminals as shown.
NOTE: Long Distance Relay Kit wiring is not required for long
distance control runs and should not be used.
Wall Control
WARNING:
• Wall Control(s) must be located so that the door is
within sight of the user.
• Attach the Warning placard adjacent to the
Wall Control. Fig. 3A.
WARNING:
If momentary contact control
is to be used, an external reversing device such as a
photocell system or sensing edge switch must be used.
See pages 5.6-5.7 for installation of entrapment
protection devices.
NOTE
JUMPER BETWEEN
STOP AND GND
TERM NALS MUST
BE REMOVED
3-BUTTON
STAT ON
CONTROL SIGNAL TERMINAL STRIP
OPEN CLOSE STOP GND
3-BUTTON
STAT ON
OPEN
CLOSE
STOP
OPEN
CLOSE
STOP
Figure 4
1-BTN
STAT ON
KEY
SW TCH
STAT ON
CARD
READER
OPEN/CLOSE
PULL SW TCH
CONTROL SIGNAL TERMINAL STRIP
ODC
STB
GNDSTOP 1-BTN
Figure 5
OPEN
CLOSE
STOP
3-BUTTON
STAT ON
CONTROL SIGNAL TERMINAL STRIP
NOTE
JUMPER BETWEEN
STOP AND GND
TERMINALS MUST
BE REMOVED
OPEN CLOSE STOP GND
Figure 3
WARNING
Moving Door can cause
serious injury or death
To prevent entrapment
Do Not start door
downward unless doorway
is clear
In ta l ont ol w ch and th s s gn so ha door s in s ght
of t e ser Do Not em ve over r pa nt ov r th s s gn
Entrapment
Warning
Placard
Figure 3A
Heavy Duty Operator
GCL-GT