Setting Travel Limits
UP LIMIT SET
Figure 7
OPEN
CLOSE
STOP
CAL
RUN
SCROLL
SCROLL
SET
CLEAR
DOWN LIMIT SET
Figure 8
NOTE: The recommended setpoint for the DOWN Travel Limit is normally at
approximately 2 inches off the floor. This final distance will be covered by the Limit
Overrun Function to establish a more accurate seal.
CAL
RUN
CAL
CROL
SET
CLEAR
OPEN
CROLL
CAL
RUN
CLOSE
Resetting Travel Limits
CAL
RUN
CAL
SCROLL
OPEN
SET
CLEAR
CAL
RUN
CLOSE
SET
CLEAR
UP and/or DOWN
1) If operator is in RUN mode, press CAL/RUN to enter calibration mode.
2) Press SCROLL until display reads “UP LIMIT>CLR ” or
“DOWN LIMIT>CLR Figure 7.
3) Jog the door using the OPEN or CLOSE key until you reach the
desired height.
4) Press SET/CLEAR key to switch display to “UP LIMIT>SET “ or
“DOWN LIMIT>SET .“ Figure 8.
5) Press a SCROLL key to shift to a new function and lock in the
limit setting.
6) Press CAL/RUN to return to run mode.
UP and/or DOWN
1) If operator is in RUN mode, press CAL/RUN to enter calibration mode.
2) Press SCROLL until display reads “UP LIMIT>SET ” or
“DOWN LIMIT>SET.” Figure 8.
3) Press SET/CLEAR to switch display to ”UP LIMIT>CLR” or
”DOWN LIMIT>CLR”
4) Jog the door using the OPEN or CLOSE key until you reach the
desired height.
5) Press SET/CLEAR to switch display to ”UP LIMIT>SET” or
”DOWN LIMIT>SET”
6) Press CAL/RUN to return to run mode.