1) For one 3 - button installation, make connections as
shown in Fig. 3.
2) For single button accessory controls, make connections as
shown in Fig. 4.
3) For a multiple 3 - button installations, make connections as
shown in Fig. 5.
NOTE: If an External STOP button is NOT being installed, a jumper wire
must be installed between the “STOP” AND “GND” terminals as shown.
NOTE: Long Distance Relay Kit wiring is not required for long
distance control runs and should not be used
Wall Control
WARNING:
Wall Control(s) must be located so that the door is within sight of
the user.
Attach the Warning placard adjacent to the Wall Control. Fig. 3A.
Attach the Caution Label adjacent to the Wall Control. Fig. 3B.
WARNING:
If momentary contact control is to be used, an external monitored reversing
device such as a photocell system or sensing edge switch must be used. See
pages 5.6-5.7 for installation of entrapment protection devices.
NOTE:
JUMPER BETWEEN
STOP AND GND
TERMINALS MUST
BE REMOVED
3-BUTTON
STATION
CONTROL SIGNAL TERMINAL STRIP
OPEN CLOSE STOP GND
3-BUTTON
STATION
OPEN
CLOSE
STOP
OPEN
CLOSE
STOP
Figure 4
1-BTN
STATION
KEY
SWITCH
STATION
CARD
READER
OPEN/CLOSE
PULL SWITCH
CONTROL SIGNAL TERMINAL STRIP
ODC
STB
GNDSTOP 1-BTN
Figure 5
OPEN
CLOSE
STOP
3-BUTTON
STATION
CONTROL SIGNAL TERMINAL STRIP
NOTE:
JUMPER BETWEEN
STOP AND GND
TERMINALS MUST
BE REMOVED
OPEN CLOSE STOP GND
Figure 3
11 35 0 1
Entrapment
Warning
Placard
Figure 3A
Figure 3B
CAUTION
To prevent the motor protector from tripping,
do not exceed 4 door operations per hour.
For light-duty use ONLY
Not for residential use.
P/N 111980.0001
5.4