3531835447 f Kaimm —— — Safety Information...............................................2 Important Installation Instructions...................... 2 Safety Features....................................................2 For 7' 6" Doors. Extension Kit is available for 8' Doors Pre-installation Checklist....................................3 Included Wall Control MUST be installed prior to Operation of this Garage Door Operator. Garage Door Opener Assembly...........................
Garage Doors are heavy objects that move with the help of springs under high tension and electric opening equipment. Since moving objects, springs under tension, and electric opening equipment may cause injuries, your safety and the safety of others depend on you reading and understanding the information in this manual. If you have garage door related questions or do not understand the information presented, call your nearest Genie Factory Authorized Dealer listed at www.geniecompany.
This Opener includes parts and supplies needed to install in most garages and connect to most garage doors. There are many variations of garages and garage doors. A few additional parts and supplies may be needed to install Opener into your garage and connect to your garage door. While checking items listed below, note any additional items you will need. Tools used in tfils sticticin: A WARNING: If your door sticks, binds, or is out of balance, have it adjusted by a Genie Factory Authorized Dealer.
Measure garage door height (7'-6", 8'-0", or taller) with tape measure. A If door height is 7'-6" or less, continue with Check Step 4. B If your door height is above 7'-6", make sure your rail is long enough to open the garage door. If there is any question contact your Customer Service Representative at 1-800-35-GENIE. SECTIONAL DOOR NOTE The header is a heavily reinforced section of the wall just above the top of the garage door opening. Find vertical center line of door and header: • Close door.
Check ceiling or space above where Opener Power Head will be mounted (Figure 5): A Measure from garage door center line mark toward rear of garage: • Approximately 10' back if garage has a 7' 6" door. • Approximately 11' back if garage has an 8' 0" door. • Approximately 13' back if garage has an 10' 0" door. • Approximately 14' back if garage has an 12' 0" door. NOTE Mounting Straps are included to attach the Opener to most garage ceilings. Garage construction varies widely.
Check for wood garage frame, jamb, or masonry at mounting location (6" above floor) with attachment tabs facing away from garage door (Figure 7). A If you cannot mount Safe-T-Beam® Mounting Bracket to wood frame: • Concrete screws and concrete anchors (not included) must be used to mount Brackets on masonry with attachment tabs facing away from garage door.
Item Part Name Qua utity Reqilired 1-Pc Rail 3-Pc Rail 1 Power Head Assembly (main carton) 1 1 2 1 /4"-20 X13/16" Hex Head Shoulder Bolt (blue bag) (yellow bolt) 2 2 3 Rail Assembly (1 piece)(packaged separately) 1 4 Rail Assembly (3 piece)(main carton) 1 4A First Rail Section 1 4B IVliddle Rail Section 1 4C End Rail Section 1 8 l/4"-20 Hex Serrated Flange Nut (blue bag) 9 Rail Clamps (blue bag) 10 5/16"-l 8 X11 /16" Hex Head Shoulder Bolt (blue bag) 11 5/16"-l 8 Hex Serrate
_________________________ NOTE________________ Opener will not function unless Safe-T-Beam® System is installed and Force Controls are properly set. One-Piece Rail Assembly (Genie Pro only) for 10' or 12' door includes; • • • Special "Close" Limit Switch with longer Wires. 96" Emergency Release Cord (yellow). Rail Support Kit. FcM' Help, call l-SOOHJSHSEiiE or ¥isit %wi»i.ferilecornparif.
Rail Strap (15 5/16"-l8 Hex Head Shoulder Bolts 5/16"-l 8 Hex Serrated Flange Nuts A Turn Power Head upside down and place on a flat B Install Bumper (Figure 9). C Install Coupler on Motor Shaft (Figure 9). A CAUTION The Drive Screw and Rail Liner can slide out of Rail Sections. Keep Rail Sections level until the Opener is fully assembled. Connect first Rail Section to Opener Power Head. Connect with 2 (l/4"-20) (yellow) Hex Head Shoulder Bolts and 2 (1/4" -20) Hex Serrated Flange Nuts (Figure 10).
A Place Magnetic Carriage Assembly Lever in "release" position. Magnetic Carriage Release Assembly ^ Position Engaged Position B Slide Magnetic Carriage Assembly into slot on End Rail Toward Section with arrow pointing away from the Power Head door and header (Figure 12).
NOTE Loosen (Do Not Remowe) Terminal Block Screws. Limit Switch adjustments and securing the Wires will be done later. F Lay Wires in channel on top of Rail and secure with Wire Clips (Figure 14). G Coil and bundle excess Limit Switch Wires on top of Power Head with Twist Ties. Leave just enough Wire to reach Terminals on back of Power Head (Figure 14). H Turn Opener upside down, and connect Limit Switch Wires to Power Head Terminal Block (Figure 15): • Terminal 4: OPEN Limit Switch Wire (white).
Mount directly into header Use of Header Bracket support board NOTE For lightweight garage doors, make sure you have installed the proper reinforcement (See Check Door Condition and Thickness on page 3). A CAUTION Alternative Header Bracket orientations The Header Bracket must be fastened to the garage framing. Do Not fasten the Header Bracket to drywall, particle board, plaster, or other such material.
(28 (5^ or (g) A CAUTION Doors made of masonite, lightweight wood, fiberglass, metal, or other lightweight materials must be properly braced before mounting door Opener. For stictional doors; A Place Door Bracket on door center line, no lower than top roller, and mark holes (Figure 19). (28) SECTIONAL DOORS ONE-PIECE DOORS Center Line of dooL,-::;:=:gi J Center Line of door . /. I OR Attach no " lower than.
SECTIONAL DOORS Rail Should be level or dip down slightly. A Raise and support Opener Power Head (along door center line) higher than highest point of door travel (using step ladder, etc.) (Figure 21). B Measure distance from Opener to garage ceiling. A CAUTION Mounting Brackets must be fastened to garage framing. Do Not fasten to drywall, particle board, plaster, or other such materials.
32 Clevis Pins Cotter Pins For stictiorial cii3ors: A Attach Curved Door Arm to Door Bracket with Clevis Pin and Cotter Pin (Figure 23). Safe-T-Beam® (STB) Brackets B Attach Straight Door Arm to Magnetic Carriage Assembly. 3/8"X 7/8" Hex Head Bolts C Attach both Arms together with 2 (3/8" x 7/8") Hex Head Bolts and 2 (3/8") Serrated Flange Hex Serial Number Nuts so overall length is as short as pos sible. Securely tighten fasteners.
Safe-T-Beam® Sensor (Green LED) @) ^ ELECTRICAL WARNING Ensure there is No power to the Opener before installing Safe-T-Beam® System Wires. If Opener is plugged into outlet, Safe-T-Beam® Source (Red LED) Unplug it now. NOTE The Opener will not close the door automatically unless the Safe-T-Beam® System is installed. Install Safe-T-Beam® Source and Sensor (Figure 25): • Mark both sides of garage door frame or wall 6" above floor. • Hold Bracket against door frame or wall.
^ CAUTION Staples which are too tight may cut or pinch Wires. Cut or pinched Wires can cause the Safe-T-Beam® System to stop working. When installing the Insulated Staples, make sure you fasten them only as tightly as needed to hold the Wire securely. Install Safe-T-Beam® Wiring (Figure 28): • Route Wire and Insulated Staples (Figure 29 and Figure 30). Securely fasten Wires with Insulated Staples as you go. Staples should be snug only.
Security Vacation A WARNING Verify there is no power to the Opener before installing Wall Console Wires. * • NOTE More than one lighted Wall Control per Opener will cause a malfunction. Wall Console (Figure 31): • Has a Security Vacation Lock Switch which disables all controls. • LED Indicator shows whether system is powered, locked, or unlocked. Makes Console easy to find in dark. • Controls door Opener from inside garage.
A electrical warning To reduce the risk of electrical shock, this equipment has a grounding type Plug that has a third (grounoing) Pin. This Plug will only fit into a grounding type outlet. If the Plug does not fit into the outlet, contact a qualified electrician to install the proper outlet. Do Not change the Plug in any way.The door Opener must be properly grounded to prevent personal injury and damage to the components.
NOTE Little effort is required to turn the Force Adjusting Knobs. Setting Close Limit Switch (Figure 34): • Check that Magnetic Carriage Assembly is disengaged. • With garage door fully closed, slide Close Limit Switch until it is aligned with Carriage Assembly Magnet. • Tighten Set Screw. Do Not over-tighten. If the door stops moving while opening or closing, adjust the Open Force or Close Force Controls slightly clockwise (to slightly increase the force) and retry the step.
________ NOTE____________ To protect your new investment, your Excelerator® is equipped with a Timer and Cycle Counter which work together to prevent any chance of heat damage to electrical circuits caused by too many cycles in too short a time. If your Opener suddenly stops responding to the Wall Console - Do Not Unplug the Unit - simply wait 10 minutes for theTimer/CycIe Counter to reset itself and try again.
NOTE Each Remote Control must be programmed separately. A To program one Button of a Remote Control (Figure 37): • Locate Learn Button and Learn Indicator Light near Terminal Block on Power Head (Figure 38). • Press and release Learn Button. Red Learn Indicator Light will blink 2 times per second. • Press Remote Control Button once within 30 seconds. Red Learn Indicator Light will stay lit. • Press Remote Control Button again. Red Learn Indicator Light will go out, indicating that memory is stored.
__________ NOTE___________ A WARNING A Moving door can cause serious injury or death. 1 Keep people clear of opening while door is moving. 2 Do Not allow children to play with Wireless Keypad. 3 During programming, the door opener could begin to run, so stay away from the moving door and its parts.To keep the door from moving, close the door and disconnect it from the Opener oy pulling the Emergency Release.
(Continued) Operating 2 or 3 Door Openers: • To move one of the doors. • Enter your PIN. • Press , Press door opener number (C1J or or Mount Keypad. (Mounting screws located inside battery compartment.) • • • • • • Remove Battery Cover. See Figure 3. Drill a 1/16" pilot hole for the top mounting screw. Install a screw into the drilled hole, leaving a 1/8" gap between the screw head and the wall. See Figure 2. Hook the Keypad over the screw. Mark,drill pilot hole and fasten bottom screw.
A Monthly: • Door springs and door hardware: - Oil door roller, bearings, and hinges using silicone lubricant or light oil. Snap Lens Hinges into slots on back of Motor Cover A WARNING 60 Watts maximum Push in Latches to close Lens Do not operate door automatically or manually if springs are broken. Contact a Genie Factory Authorized Dealer for service or call Customer Service at 1-800-35-GENIE. • Balance Door. - Close door.
^WARNING TO REDUCE THE RISK OF SEVERE INJURY OR DEATH 1 READ AND FOLLOW ALL INSTRUCTIONS. 2 Never let children operate or play with the Door Controls. Keep the Remote Control away from children. 3 Always keep the moving door in sight and away from people and objects until the door is completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR. 4 NEVER GO UNDER A STOPPED, PARTIALLY OPEN DOOR. 5 Test Opener monthly.
Of See Status Light on FigureSS, page 22) u See 1 BLINK, 1 Pause (Repeat) ablem /Vhat to Do 1 Motor Drive Board Interrupt e Reset Opener—unplug (or disconnect power), wait 5 seconds, plug back in (reapply power), and activate from Wall Console. Normal . operation restored « First Cycle will run at slow speed. Reference 1 1 If the problem recurs « Operation not restored « « Check door condition. NOTE: This Opener is equipped with an automatic garage door balance detection system.
Problem What To Do 1. Check power source. Opener does not run from Remote Control A. If Opener is connected to an outlet: • Plug a working lamp into outlet used for Power Head. • If lamp glows, power source and outlet are OK. • If not, check fuse or circuit breaker or non-compatible GFCI. NOTE: A licensed electrician must replace non-compatible GFCI's. B. If Opener is connected to a wiring box: • Check fuse is not blown, or circuit breaker is "Closed" (not tripped).
C5eri
To get warranty service for your Genie product, you must provide proof of date, and place of purchase of the product. What is Cmemd Any defect in material and workmanship from personal, normal household use in accordance with the Owner’s Manual. For How Long:; H8000D Series — Lifetime* on motor, on parts and service. ISD990 Series — Lifetime* on motor, 5 years* on parts. ISD990-2 Series — Lifetime* on motor and all parts. ISD99S Series — Lifetime* on motor and all parts.
ài (GIT-1) Deluxe Remote Control with Intellicode®- Allows remote operation of garage door Controlador remoto de lujo con Intellicode®- Proporcionar operación remoto de la puerta del garaje Télécommande de luxe avec Intellicode®- Permettre opération éloign"de porte de garage (GIT-2) 2-Button Remote Control with Intellicode®- Allows remote operation of 2 garage doors Controlador remoto de 2 funciones con Intellicode®- Proporcionar operación remoto de dos las puertas del garaje Télécommande à 2 fonctions avec
I& MODEL MODELO DESCRIPTION DESCRIPCIÓN MODÈLE DESCRIPTION PRODUCT CODE CÓDIGO PRICE (US$)* QTY. PRECIO* CANTIDAD CODE DU PRODUIT PRIX ($ US)* GIT-1 Deluxe Remote Control with Intelllcode® Controlador remoto de lujo con Intelllcode® Télécommande de luxe avec Intelllcode® 33069R $34.95 GIT-2 2-Button Remote Control with Intelllcode® Controlador remoto de 2 funciones con Intelllcode® Télécommande à 2 fonctions avec Intelllcode® 33069S $44.