What To DoProblem
Remote Control has less
than 25' operating range
Opener works from Wall
Control, but not from
Remote Control
Noisy operation
Safe-T-Beam® System
Door closes,and Opener
shuts clown
. Relocate Remote Control inside car.
. Ensure Remote Control is pointing toward garage door when pressing Control Button.
• Replace Remote Control Battery _EVB?EAD_ type"A23." (See page 22).
• Reposition Opener Antenna Wire.
• Do Not attem t to retune Remote Controls or Receiver
• Program code for each Remote Control into Receiver memory (SeeProgramming the Remote
Control on page 22.
. Replace Remote Control Battery _EIfB?EAD_ type"A23." (See page 22).
• Check Safe-T-Beam® System for beam obstruction or misalignment of Lenses.
• Check Safe-T-Beam® System for any diagnostic codes. If present, troubleshoot as detailed in
Safe-T-Beam® System Self-Diagnostic Troubleshooting Chart (See page 26).
• Ensure all fasteners are tightened.
• Check that the garage door and Opener are in good repair, properly lubricated, and properly
balanced. (SeeMaintenance page 25).
• If you suspect a problem with garage door hardware or springs, contact a Genie
Factory Authorized Dealer for s rvice,orcontact Customer Serviceat 1-800-35-GENIE
• If an operational problem exists, Opener will not run closed.
• Check Safe-T-Beam®Systemfor beam obstruction or misalignment of Lenses.
• Check Safe-T-Beam®Systemfor any diagnostic codes. If present,troubleshoot asdetailed in Safe-T-Beam®
SystemSelf-DiagnosticTroubleshooting Chart (Seepage 26).
• Check position of Wall ConsoleVacationLockSwitch. It must be in UNLOCKEDposition for Opener to
open door.
WALL CONTROL
m
_u
i-
o3
WHITE
1 WHITE __
i OPEN LIMIT z
Opening Cover May Cause Electric Shock [
CONTROLLER BOARD
-@
®
-@
J_
-@
PRIMARYGROUND
MOTOR DRIVE BOARD
GREEN
l LiNE
PLUG
I 9 BLUE
I 8 BLACK
WHITE
6
WHITE
5
_ o
MOTOR
GREEN
_1_
SECONDARYGROUND