Manual

What To DoProblem
Remote Control has less
than 25' operating range
Opener works from Wall
Control, but not from
Remote Control
Noisy operation
Safe-T-Beam® System
Door closes,and Opener
shuts clown
. Relocate Remote Control inside car.
. Ensure Remote Control is pointing toward garage door when pressing Control Button.
Replace Remote Control Battery _EVB?EAD_ type"A23." (See page 22).
Reposition Opener Antenna Wire.
Do Not attem t to retune Remote Controls or Receiver
Program code for each Remote Control into Receiver memory (SeeProgramming the Remote
Control on page 22.
. Replace Remote Control Battery _EIfB?EAD_ type"A23." (See page 22).
Check Safe-T-Beam® System for beam obstruction or misalignment of Lenses.
Check Safe-T-Beam® System for any diagnostic codes. If present, troubleshoot as detailed in
Safe-T-Beam® System Self-Diagnostic Troubleshooting Chart (See page 26).
Ensure all fasteners are tightened.
Check that the garage door and Opener are in good repair, properly lubricated, and properly
balanced. (SeeMaintenance page 25).
If you suspect a problem with garage door hardware or springs, contact a Genie
Factory Authorized Dealer for s rvice,orcontact Customer Serviceat 1-800-35-GENIE
If an operational problem exists, Opener will not run closed.
Check Safe-T-Beam®Systemfor beam obstruction or misalignment of Lenses.
Check Safe-T-Beam®Systemfor any diagnostic codes. If present,troubleshoot asdetailed in Safe-T-Beam®
SystemSelf-DiagnosticTroubleshooting Chart (Seepage 26).
Check position of Wall ConsoleVacationLockSwitch. It must be in UNLOCKEDposition for Opener to
open door.
WALL CONTROL
m
_u
i-
o3
WHITE
1 WHITE __
i OPEN LIMIT z
Opening Cover May Cause Electric Shock [
CONTROLLER BOARD
-@
®
-@
J_
-@
PRIMARYGROUND
MOTOR DRIVE BOARD
GREEN
l LiNE
PLUG
I 9 BLUE
I 8 BLACK
WHITE
6
WHITE
5
_ o
MOTOR
GREEN
_1_
SECONDARYGROUND