See Status Light on Figure38, page 22)
You See
1 BLINK,
Pause
(Repeat)
2 BLINKS,
Pause
(Repeat)
3 BLINKS,
Pause
(Repeat)
4 BLINKS,
Pause
(Repeat)
5BLINKS,
Pause
6 BLINKS,
Pause
7 BLINKS,
Pause
8 BLINKS,
Pause
Problem
Motor Drive
Boa rd
Normal
operation
restored
If the problem
recurs
Operation not
restored
Controller
Boa rd
Interrupt
Opener
Overheated
or
Force Settings
Incorrect
Safe-T-Beam ®
Malfunction
Wall Console
does not work
Limit Switches
not working
Wall Console
locked
What to Do
Reset Opener--unplug (or disconnect power), wait 5 seconds, plug
back in (reapply power), and activate from Wall Console.
First Cycle will run at slow speed.
automatic garage door balance detection system. An improperly
balanced door, damaged or worn counter-balance spring, binding
door hardware or rollers may result in a "ONE-BLINK" signal.
Contact Customer Service for further assistance.
Check door condition.
Have a Genie Factory Authorized Dealer check:
- Fuse on Motor Drive Board.
- Ribbon Cable on Motor Drive Board is properly inserted into
Connector on Controller Board.
Reset Opener- unplug (or disconnect power), wait 5 seconds, plug
back in (reapply power), and activate from Wall Console.
Have a Genie Factory Authorized Dealer check that Ribbon Cable on
Motor Board is properly inserted into connector on Controller Board.
Do not unplug or disconnect power from Opener. Wait 10 minutes
for internal clock to provide additional cycles. Cycles are restored
at a rate of S cycles per 10 minutes of rest.
Check Force Settings. NOTE: Force Settings are not pre-set at factory.
Check door condition.
Check Safe-T-Beam ® Self-diagnostk System. NOTE: Safe-T-Beam ®
System must be installed and operational to enable door to close.
Check Wall Console Wiring for shorts, tight Staples, or pinched Wires.
Check Wiring Connections at Power Head and Wall Console.
Check Limit Switch Wire connections to Terminals on Power Head.
Check for shorted or pinched Wires under Limit Switch Brackets.
Vacation Locking Switch on Wall Control is in "Lock" mode.
Unlock switch.
NOTE
Reference
See Door
Safety Guide
1. See page 3.
2. See door
Safety Guide
1.See page 20.
2.See Door
Safety Guide_
See page 16.
See page 18.
See page 20.
See page 18
The status LED Indicator Light is located under the Lens Cover.The Green LED light will turn ON,then OFFwhen
power is applied to the Opener. If LED stays ON, have a Genie Factory Authorized Dealer check the Controller
Board, or call Customer Service at 1-800-35-GENIE.
®
If Safe-T-Beam problems exists,the door can be closed electrically by holding the Wall Console Button down
until door is fully closed.