LOCATING SAFE-T-BEAM® PAIRS
Transmitter (RED LED) and Receiver (GREEN LED)
Single Garage Door
• Determinewhichsideofthegaragereceivesdirectsunlight.
• PositiontheTransmitter(RedLED)onthedirectsunlightside.
Multiple Garage Doors
•
NEVER position Safe-T-Beam® modules where signals will cross.
• PlacetheTransmitter(RedLED)Safe-T-Beamsonadjacentdoors
facing in opposite directions.
NOTE:
Direct sunlight creates interference with Safe-T-Beam
®
Receiver (Green LED). STB modules CAN be positioned further
away from the door opening if necessary to avoid sunlight
but no further o the wall to maintain alignment with the
Transmitter (Red LED) module.
NOTE: Only use Safe-T-Beams® that are included with this opener. DO NOT use other brands or types of
photocells on this opener.
Installing Safe-T-Beams® on multiple garage doors (Preventing “cross-talk”)
Installing the Battery Backup:
For units that included the optional battery backup (BBU)
1. Unplug powerhead from power source.
2. Tilt BBU approximately 45 and lower into slots
in the top rear of the powerhead.
3. Fasten to powerhead with 2 supplied self
tapping screws.
NOTE: There are no holes in rear cover. Self Tapping
screws will self tap through cover.
4. Plug battery harness into plug located at the
top of the powerhead.
5. Reconnect powerhead to power source.
45
Testing The Genie Battery Backup
NOTE: It is recommended that the battery backup be allowed
to charge for 48 hours prior to testing. Initially, the opener may not operate
from the battery backup mode if battery is not fully charged.
1. Run the opener using the wall control or remote to ensure it is working properly.
2. Turn o power to opener by unplugging from outlet or turning o breaker.
3. Press wall control or remote control. Opener will run at a slower speed than normal.
NOTE: See troubleshooting guide in this manual if any of the steps above fail.
Work light will not operate while in battery backup mode. (Courtesy white LED’s will illuminate.)
4. After successful test, reconnect powerhead to power source.
See the troubleshooting pages for condition LED’s That will illuminate
once the Battery Backup is operational.
BothLEDswillsignalsolidGREENundernormal,fully
charged,conditions.
TO PREVENT POSSIBLE
SERIOUS INJURY or DEATH
from electrocution AND REDUCE RISK of FIRE
— Disconnect ALL electric power sources and battery
power BEFORE performing ANY service or maintenance.
Install only in DRY locations - NOT INTENDED FOR OUTDOOR USE.
Use only 12V, 5AH, SLA replacment battery
(P/N 111658.0002.S).
CAUTION
Installer uniquement dans des endroits secs—NE DOIT PAS ÊTRE
UTILISÉ À L'EXTÉRIEUR.
Utiliser uniquement une pile de remplacement de 12V, 5AH, SLA
(réf. 111658.0002.S).
POUR ÉVITER LES BLESSURES
GRAVES VOIRE MORTELLE PAR
ÉLECTROCUATION POUR RÉDUIRE ES LES RISQUES
D'INCENDIE
—Débrancher toutes les sources d’alimentation électriques et
la pile avant d'eectuer des opérations de réparation ou
d'entretien.
ATTENTION
Battery backup devices from other manufacturers will not operate with this opener.
Use only Genie Battery Backup type battery that was provided. Genie P/N 111658.0002.S (Battery only)
Perform these steps only after opener is fully installed, programmed and tested.
Installing Battery Backup