Garage Door Opener User Manual

Problem
Openerdoesnot run
from WallControl
Door Opener starts
for no apparent reason
Door starts down, then
stops before it is
completely closed
Door starts down, then
stops and goes backup
Door will only run closed
Doorwill onlyrunopen
Lights will not turn off
Door startsup,
but stops beforeit is
completelyopen
Operator runs, but door
does not move
Wall ConsoleVacation
Lockfunction does
not work
Noisy Operation
General Troubleshooting
What To Do
1. Check Lock switch on Wall Control Installation Poster.
2. Check Power Source:
• For Grounded Plug Connection.
- Plug a lamp into the electrical outlet used for the door opener.
a. If lamp lights, power source is good.
b. If lamp does not light, check fuse or circuit breaker.
• For Permanent Wiring Connection.
- Check fuse or circuit breaker.
3. Check connections (see Wall Console Installation on Installation Poster):
• At Power Head Terminals and Wall Control.
1. Check Wires to ensure that they are not cut (Staples can cut insulation and short Wires)
Replace any shorting Staples and shorted Wires.
2. Was Remote Control lost or stolen? If so, erase all Remote Control codes from Receiver's memory
and reprogram for remaining remote controls. (See EraseAll Receiver Memory on page 8).
3. Ensure that no Buttons are stuck "pushed-in" on Wall Console or any Remote Controls.
1. Check Close Limit Switch setting (page 7 and poster). Adjust as needed.
2. Check Force Setting (pages 7).Adjust as needed.
3. Check for shorted wires.
1. Ifa new installation, check Door Arm position.
2. Check operation of Contact Reversefunction.
3. Check Safe-T-Beam®Systemfor beam obstruction or misalignment of Lenses.
4. Check Safe-T-Beam®System diagnostic code.
5. Check CloseForceadjustment (seeSet Limit Switchesand Force Controls on pages 7). Adjust as needed.
6. Check garage door for binding.
1. Check Open Limit Switch for a short circuit and for proper wiring.
2. Check Open Force adjustment (seeSetLimit Switches and ForceControls on pages 7). Adjust as needed.
3. Check condition of garage door and door spring(s).
4. WARNING: If you suspecta problem with the garage door hardware or springs,contact a Genie
FactoryAuthorized Dealer for service,or contact Customer Serviceat 1-800-35-GENIE.
5. CheckPosition of Lock Switch on Console.
1. CheckSafe-T-Beam®Systemas detailed in the Safe-T-Beam®System Self-diagnosticTroubleshooting Chart
(page 10).
2. CheckCloseLimit Switch for a short circuitand for proper wiring.
3. CheckCloseForceadjustment (seeSet Limit Switchesand Force Controlson pages7). Adjust asneeded.
1. Disconnect Wires connectingPushbutton to Power Head(seePushbutton Installation on poster).
Checktheir conditionand either replaceor reconnect.
2. Until a replacement Wall Consolecan be obtained, disconnect Wall Consoleand use only Remote Controls
or Wireless Keypadto operate Opener.
3. Checkfor non-compatible wall control.
1. Check(ensure) that garage door and Opener are in good repair, properly lubricated, and properly
balanced as detailed in Maintenance Section.
2. WARNING: If you suspecta problem with the garage door hardware or springs,contact a Genie Factory
Authorized Dealer for service, orcontact Customer Serviceat 1-800-3S-GENIE.
3. CheckOpen Limit Switch for a short circuitand for proper wiring.
4. CheckOpen Forceadjustment (seeSetLimit Switchesand ForceControlson pages7). Adjust as needed.
1. EnsureCarriageAssembly is engaged to CarriageSlide (seeInstallCarriageAssemblyonto Railson InstallationPoster).
2. CheckForceadjustment (seeSet Limit Switchesand Force Controlson pages 9 and 10). Adjust as needed.
1. EnsureCarriageAssembly is in contactwith CloseLimit Switch.
2. Checkwhen door isfully closed,that Carriageactivates CloseLimit Switch. If not, adjust position of Close
Limit Switch (Seepages 7).
1. Be sure all fastenersare tight.
2. Check(ensure) that garage door and Opener are in good repair, properly lubricated, and properly
balanced as described in Maintenance Section (page 10).