SDS

Page 4/10
Safety Data Sheet
29 CFR 1910.1200
Printing date 02/15/2019 Reviewed on 01/23/2019Version number 1
Trade name:
Lithium battery ISR18650 3.7V 2000mAh
(Contd. of page 3)
48.1.25
Use respiratory protective device against the effects of fumes/dust/aerosol.
Mount respiratory protective device.
Wear protective equipment. Keep unprotected persons away.
·
Environmental precautions:
Do not allow to enter sewers/ surface or ground water.
·
Methods and material for containment and cleaning up:
Use neutralizing agent.
Ensure adequate ventilation.
Dispose contaminated material as waste according to item 13.
7 Handling and storage
·
Precautions for safe handling:
Avoid contact with eyes.
Keep away from heat and direct sunlight.
Prevent formation of dust.
Prevent short cut and movement which could lead to short circuits.
Thorough dedusting.
Ensure good ventilation/exhaustion at the workplace.
Open and handle receptacle with care.
For the general occupational hygienic measures refer to Section 8.
·
Information about protection against explosions and fires:
Keep respiratory protective device available.
·
Conditions for safe storage, including any incompatibilities
·
Requirements to be met by storerooms and receptacles:
Store in a cool location.
Store only in the original receptacle.
·
Information about storage in one common storage facility:
Store away from foodstuffs.
Store away from flammable substances.
·
Further information about storage conditions:
Keep receptacle tightly sealed.
Store in cool, dry conditions in well sealed receptacles.
8 Exposure controls/personal protection
·
Components with limit values that require monitoring at the workplace:
7440-50-8 copper (16.0%)
PEL (USA) Long-term value: 1* 0.1** mg/m³
as Cu *dusts and mists **fume
REL (USA) Long-term value: 1* 0.1** mg/m³
as Cu *dusts and mists **fume
TLV (USA) Long-term value: 1* 0.2** mg/m³
*dusts and mists; **fume; as Cu
7782-42-5 Graphite (15.0%)
PEL (USA) Long-term value: 15 mppcf* mg/m³
*impinger samples counted by light field techn.
REL (USA) Long-term value: 2.5* mg/m³
*respirable dust
TLV (USA) Long-term value: 2* mg/m³
all forms except graphite fibers;*resp. fraction
(Contd. on page 5)
USA