Installation Guide
Troubleshooting T
i
p
s
P
r
o
b
l
e
m
The GenerLink will not transfer to the generator during testing with utility power
present.
C
a
u
se
The GenerLink unit is equipped with a lockout circuit that prevents transfer to
generator power if the load on the home exceeds 50-amps. The yellow status light
will be illuminated if the load exceeds 50-amps
So
l
u
t
i
o
n / TESTING
1. Disconnect the generator.
2. Reduce the load by turning off ALL the circuit breakers in the house
3. Confirm that the yellow status light is not illuminated
4. Reconnect and restart the generator.
5. Restore load equal to or less than the capacity of generator.
6. Operate household loads using your generator.
7. Do not, under any conditions, attempt to remove or repair GenerLink yourself
P
r
o
b
l
e
m
GenerLink will not continuously connect the generator to the loads or it periodically
cycles the loads on and off.
C
a
u
se
GenerLink is equipped with load sensing capabilities. If it detects a connected load
that exceeds the 50 amp continuous load rating, it will automatically disconnect the
generator for a short period of time.
So
l
u
t
i
o
n
Reconnect GenerLink through a 20-amp 30-amp or 50-amp connector.
P
r
o
b
l
e
m
The green indicator light on GenerLink is not illuminated when utility power is
present.
C
a
u
se
The green status light on the bottom of the GenerLink must be illuminated when
utility power is present. If it is not illuminated, this may indicate an abnormal
condition that may require service.
So
l
u
t
i
o
n
1. Call for service. (Refer to the Terms and Conditions for service instructions)
2. Do not attempt to test or use the GenerLink with a generator until the condition
is corrected.
3. Do not, under any conditions, attempt to remove and/or repair GenerLink
yourself.