Installation Guide
Technical Fact S
h
ee
t
GenerLink 
Specifications 
and Technical 
In
f
o
r
m
a
ti
on
Ph
ys
i
c
a
l 
Diameter:  6 ½ in. 
Depth:  5  ¼  in. 
Weight w/o surge:  5  ½  lbs 
Weight with surge:  5 ¾ lbs 
Socket Style:  Ring or Ring-less, 200 Amp, 4 jaw 
E
l
ec
t
r
i
c
a
l 
Source Compatibility:  200 Ampere Service or Less 
Withstand Current:  10,000 Amperes rms symmetrical at .5 
pf, 240 Volts, 60 Hz 6000 Amperes 
for 6 cycles at .7 - .8 pf, 240 Volts, 60 Hz 
Generator Input: 
10kW Continuous
†
, 120/240 Volt 
Connection:  7.2kW Continuous
† 
for MA23 
Proprietary GenerLok™ QuickConnect Power
‡
Cord
‡
O
p
e
r
a
t
i
o
n
a
l 
Transfer Type:  Break–Before–Make 
Transfer Delay:  2-3 Seconds 
Life Cycle:  300,000 Operations 
Temperature Range:  -30°C to 60°C External Ambient 
F
e
a
t
u
r
es
Generator Input Protection:  Generator Input Voltage > 200 Volts 
Supplemental Overcurrent < 40 A 
Utility Input Protection:  Utility Input Voltage > 180 Volts 
Over-Temperature Trip > 105°C 
Load Protection:  Integrated Whole-House 
Surge Protection 
(Optional) 
Status Indication:  Long-life LED indicators show utility power 
availability and/or fault presence 
† 
3 hours at 25° C/ 77° F ambient 
‡ 
Sold Separately 
* When protected by max 200 A circuit breaker in series with 100 A branch circuit breaker 