STEP 9: If the generator’s circuit breaker trips off during operation or setup, turn
off all circuit breakers in the breaker panel, reset the circuit breaker on the generator,
and restart the generator if necessary. Select and reconnect loads following the
procedures summarized in Step 7.
STEP 10: To determine when utility power has been restored, check the green
status light (see Status Lights section in this manual). If the green light is
illuminated, utility power is present and you can reconnect to the utility.
To reconnect to your electric utility:
A. Turn off your generator. Expect to hear a ‘clicking’ sound from the
GenerLink unit when the power transition occurs. This is a simple
verification that normal utility service has been restored.
B. On your breaker panel, set all circuit breakers to the ‘on’ position.
C. You can now unplug the generator from GenerLink. To unplug GenerLink,
gently pull down on the metal locking ring at the top of the GenerLok
connector. (See Diagram 5) Store your power cord in a safe and dry location.
Diagram 5