Installation Sheet

1
Installation Instructions for
Logan Small, Medium and Large Pendant
1.0
TP1051-TP1061-TP1071
Pendant
T 1051, T 1061, TP1071PP
GP I :ENERAL RODUCT NFORMATION
These fixtures are intended to be installed utilizing NEC compliant junction
boxes.
This product is safety listed for damp locations.
Incandescent lamps may be dimmed with a standard incandescent dimmer.
LED lamps may be dimmed with a LED dimmer. Consult lamp manufacturer
for additional information.
This instruction shows a typical installation.
1
2
1A
3
CAUTION RISK OF FIRE-
This product must be installed in accordance with the
applicable installation code by a person familiar with the
construction and operation of the product and the hazards
involved.
Use minimum 90°c supply conductors.
Secure the mounting plate to the junction box.
Determine the wanted height of the fixture by feeding the cord through the canopy cap, canopy and threaded rod by moving the
cord up or down. Place the cord in between the two cord clips and secure it in place using the clip screws.
Trim the cord leaving enough for electrical connections. From the end of the cord, strip the insulation 4” and then strip the end of
the wires. Make sure not to nick the inner wires.Note:
Connect the fixture to a suitable ground in accordance to local electrical codes.
Connect the white fixture wire (square and/or rigid) to the neutral power line wire with a wire nut.
Connect the black fixture wire (round and/or smooth) to the hot power line wire with a wire nut.
Neatly place all the wires into the junction box, place the canopy onto the threaded rod, and secure it in place by screwing the
canopy cap onto the threaded rod.
Screw the lamp into the socket. Refer to the label on the socket for Max Wattage Information.
4
5
6
7
8
MOUNTING PLATE
CANOPY
THREADED ROD
8
LAMP
CORD
CORD CLIP
CLIP SCREW
2
3
CORD
6
JUNCTION BOX
5
CANOPY
CAP
7