Installation Guide
Installation And Safety Instructions
Line art shown may not exactly match the fixture enclosed. However, the installation instructions do apply to
this fixture. Fill in Item Number on Carton and File This Sheet For Future Reference. ITEM#_______________
HC-958
0
63008
1) INSTALLING FIXTURE TO CEILING
Joist type ceiling: Extend bar hangers to fit between joists.
Position fixture temporarily by hammering nail-in tabs into
joists (see Drawing B), then secure permanently with nails.
Hangers should be level with bottom of joists.
(2) ELECTRICAL CONNECTION
Junction box contains two wires, a black (hot) and white
(neutral) which must be spliced to the house wires. MAKE
SURE TO SPLICE WHITE TO WHITE AND COLORED
OR BLACK TO BLACK. After splicing has been completed,
insert wires carefully into junction box. Connect green
ground wire to green grounding pigtail in junction box (see
Drawing B). Replace cover.
(3) CUTTING A HOLE
Locate the center of proposed opening on your tile or
ceiling material and mark it. Use the template provided to
draw a 6 3/8" dia. circle around the center point.Cut along
the circular line. (see Drawing C).
(4) FOR INSTALLATION FROM BELOW IN A FINISHED
CEILING (IF APPLICABLE)
Cut hole as in Step 3 (see above). Bring power to hole
from above and pull flex or Romex through ceiling.
Remove bar hangers and discard. Remove housing from
plaster frame by removing four sheet metal screws. Using
strong pliers, break out section of plaster frame on the
short side of plaster frame. Make electrical connection to
outlet box. Holding plaster frame on edge, pass edge of
ceiling through breakout slot, rotate frame, and pass
housing into ceiling opening. Re-install housing into the
plaster frame and set in ceiling hole.
CAUTION: SEE WARNING INSTRUCTIONS ON BACK BEFORE
PROCEEDING
WARNING: FOR FIXTURES PROVIDED WITH 75° C. OR 90° C. SUPPLY
WIRE WARNING ONLY (THESE WARNINGS ARE PROVIDED ON THE
LABEL AND ON THE FIXTURE CARTON).
WARNING: RISK OF FIRE. MOST DWELLINGS BUILT BEFORE 1985
HAVE SUPPLY WIRE RATED 60° C. CONSULT A QUALIFIED
ELECTRICIAN BEFORE INSTALLING.
1119 AND 11019 AIRTIGHT SHALLOW IC HOUSING.
FOR DIRECT CONTACT WITH INSULATION
ALLOW
1/2" SPACE
2" X 8"
1/2" TO 1" THICK
CEILING MATERIAL
BREAK OUT
THIS SECTION
(IF APPLICABLE)
PLASTER
FRAME
7 1/2"
JOIST
BAR HANGER
POWER LEAD
GROUND
TAB
A
B
C
THE 1119 AND 11019 HOUSING IS ENGINEERED FOR SHALLOW
APPLICATIONS, WHERE 2" X 6" JOISTS AND INSULATION ARE
E
NCLOSED BOTH TOP AND BOTTOM, ALLOWING FOR A MAX. OF
1/2" UNCOMPRESSED INSULATION. BY PASSING THE SOCKET
BRACKET STOP MAY CAUSE THE LIGHT TO CYCLE ON AND OFF OR
NUISANCE TRIP.
T
itle 24 - This recesses can complies with California Title 24 zero
clearance insulation cover and airtight requirements when installed with
one of the manufacturer’s certified airtight (AT) shallow housing trims and
installed per the manufaturer’s safety instructions and national and local
codes. This recessed can is rated for direct insulation cover (IC) by
Underwriters Laboratory; it has been certified airtight in accordance with
ASTM E283, and it is High Efficacy in accordance with Section 150(k) 1 of
the California 2005 Building Energy Efficiency Standards. Depending
upon the specific application, lighting controls or occupancy sensors may
also be required to meet the requirements of California Title 24.