Installation Guide

INSTALLATION INSTRUCTIONS 041108 HC-1343
(1) CUTTING A HOLE
Locate the center of proposed opening on your
tile or ceiling material and mark it. Use the
template provided to draw a 6 3/8" dia. circle
around the center point. Cut along the circular
line.
(2) ELECTRICAL CONNECTION
Junction box contains two wires, a black (hot)
and white (neutral) which must be spliced to the
house wires. MAKE SURE TO SPLICE WHITE
TO WHITE AND COLORED OR BLACK TO
BLACK. After splicing has been completed,
insert wires carefully into junction box. Connect
green ground wire to green grounding pigtail in
junction box (see Drawing A). Replace cover.
(3) INSTALLING FIXTURE TO CEILING
Slip outlet box, then housing through hole in
ceiling. Install (3) clips through “T” slots in
housing (Drawing C). Make sure clips are
completely extended from housing so fixture is
supported in ceiling (Drawing D).
(4) INSTALL TRIM ASSEMBLIES
CAUTION: SEE WARNING
INSTRUCTIONS ON BACK BEFORE
PROCEEDING
WARNING: FOR FIXTURES PROVIDED
WITH 75° C. OR 90°C. SUPPLY WIRE
WARNING ONLY (THESE WARNINGS
ARE PROVIDED ON THE LABEL AND
ON THE FIXTURE CARTON).
WARNING: RISK OF FIRE. MOST
DWELLINGS BUILT BEFORE 1985
HAVE SUPPLY WIRE RATED 60° C.
CONSULT A QUALIFIED ELECTRICIAN
BEFORE INSTALLING.
A
B
C
D
POWER
LEAD
GROUND
CLIP
“T” SLOT
11018 IC REMODEL HOUSING
FOR DIRECT CONTACT WITH INSULATION
BY PASSING THE SOCKET BRACKET STOP MAY CAUSE
THE LIGHT TO CYCLE ON AND OFF OR NUISANCE TRIP.
CLIPS