IMPORTANT INSTALLATION INSTRUCTIONS
GF-1137L model fan-power humidifier has a built-in transformer.
A 24V SPST (Single-Pole Single-Throw) relay is field supplied by contractor
and required for model 1137L installation.
DO NOT connect yellow wires to furnace board.
DO NOT use red wires in installation.
ONLY connect yellow wires as follows:
- Load side of 24V relay (C) to (C) on GF-MHX3 Humidistat.
- Load side of 24V relay (NO) wired with yellow wire on humidifier. Then
connect, the other yellow wire on humidifier to (NO) on Humidistat to
complete the circuit.
- Coil side of relay wired to C/W for heat call at Control board of furnace