Instruction Manual

1
DH70 - Crawl Space, Attic or Basement
Whole House Dehumidifier
Installation & Owners Manual
Specifications
• Model:DH70
• Capacity:70pints/day,(3.25lbs./hr)@80°/60%RH
• Electrical:110-120VAC,6.7FLAAmps,60Hz,grounded
• OperatingReturnAirTemp.Range:50°Fmin.,90°Fmax.
• AirFlow:
• 280CFMwithoutexternalducting
• 235CFM@.30IWGexternalstatic
• 195CFM@.50IWGexternalstatic
• RefrigerantCharge:17.5oz.R-410A
• Ductconnections:Returnductange:8”Round,Outlet8”Round,
• FilterSize:HighEfciency(MERV11):Pleated11-3/4”X11-3/4”X2”
• Size(Clearance):14”Heightx26”Widthx14”Depth,12”minimumfrontorrearclearanceforlterservice.
• Weight:65pounds(ShippingWeight80pounds)
Read and Save These Instructions
FORMNO.DH70REVA
Humidistat
27.25
23.25
13.00
12.75
13.75
13.00
Return
Supply
8" 8"
Filter Access
Filter Access
Filter Access
3/4" NPT Drain
3/4" NPT Drain Option
Factory Installed Plug
Grounded 120 V Power Cord - 90"
Service Access
Ajustable Legs 1/4"- 1"
Low Voltage TerminalHumidistat
LEFT SIDE VIEW
TOP VIEW
FRONT VIEW
RIGHT SIDE VIEW
BACK VIEW
DH 70
Read the installation operation and maintenance instructions carefully before installing and using this unit.
Proper adherence to these instructions is essential to obtain maximum benefit from the DH70 system.
Installation contrary to these guidelines or lack required maintenance will void warranty.
Unit Location
TheDH70canbeinstalledinavarietyoflocationstomeetthe
owner’sneedsaslistedbelow.Inallcaseskeepthefollowing
cautionsinmind:
• Theunitisdesignedtobeinstalledindoorsinaspacethatis
protectedfromrain,oodingand/orotherformsofexcesswater.
Unitisnotdesignedtobeexposedtochlorinatedpoolconditions
orspaceswhereunitwillbeexposedtocorrosivechemicalsor
conditions.
Installtheunitwithspacetoaccessthefrontpanelfor
maintenanceandservice.Alsoalloweasyaccesstothelter
coverpanel.DO NOT INSTALL THE UNIT WITH THE FRONT
PANEL OR FILTER COVER PANEL INACCESSIBLE.
• Avoiddischargingtheairdirectlyatpeople,overthewaterinpool
areas,orotherareasorobjectswheredehydrationorevaporation
ofmoistureisnotdesired.
• Ifusednearwetareas,becertainthereisNOchancetheunitcouldfallintothewaterorbesplashedandthatitis
wiredintoaGROUNDFAULTINTERRUPTERprotectedcircuit(seelocalcodesforotherrequirements).
• AsecondarydrainpanMUSTbeplacedundertheunitifinstalledabovealivingareaoraboveanareawherewater
leakagecouldcausedamage(seelocalcodesforotherrequirements).
• DO NOTlocatetheDH70directlyonstructuralmemberswherenoiseorvibrationmaybeobjectionable.TheDH70
isequippedwithadjustablesupportfeettoraiseandleveltheunitfromthemountingsurface,theseadjustablefeet
shouldbeutilizedtoprovideimproveddrainagefromthedrainpanandshouldbeadjustedtotiltslightlytowardthe
drainutilized.