Spec Sheet

MHX3C
Manual Humidistat
GFI #7038
Included
Wiring Illustration
The humidifier is connected to the 120V AC circuit through a control relay. The
secondary coil of an isolation transformer, a diode and resistor supply 5-10 volts DC
for the control circuit which also includes the humidistat and relay coil. When the
control circuit is completed by the humidistat, the relay closes, supplying 120 volts to
the fan motor and solenoid valve.
Typical Installation
1137 Installed on the warm air plenum.
16” W
14” H
10” D
Spec Sheet
Canadian General Filters, Ltd.
400 Midwest Rd.
Toronto, ON M1P3A9 Canada
Toll Free: (888) 216-9184
www.cgfproducts.com
General Filters, Inc.
43800 Grand River Avenue
Novi, Michigan 48375
Toll Free: (866) 476-5101
www.generalaire.com
GENERAL FILTERS
INCORPORATED
Legacy Series Humidifier
Residential Whole-House (GFI #5137)
GeneralAire
®
Models 1137
Fan Powered Flow Through Humidifier
1137 (GFI #5137)
Type Fan Powered Flow Through Humidifier
GPD 18 Based on 120° Plenum Temperature
Warranty (Years) 5
Replacement Vapor Pad® 990-13 (GFI#7002) (Replace 1-2 Times Per Season)
Dimensions (Inches) 14 H x 16 W x 10 D
Weight (Pounds) 19
Home Size (Sq. Ft) To 3,000
Installation Warm Air / Return Air Plenum
Plenum Opening (Inches) 15 W X 9.5 H
Bypass Opening (inches) 6
Pallet Qty. 21
Cabinet Construction Ultra-Violet Stable Automotive Grade Plastic
Humidistat MHX3C
In Box Humidifier, humidistat, Installation Instructions, Vapor
Pad®, Parts Kit, Water Tube Kit, Humidistat Wire,
Drain Pan, Power Supply Cord, Water Distribution
Trough.
Voltage 120V

Summary of content (2 pages)