Connectdrain hose to lt2" spout on humidifier cabinet using hose clamp if
necessary, Run 112" hose to suitable drain such as floor drain, sewer or _aundry
sink, Be sure hose has continuous slope and is not kinked at any point.
Turn on water supply and check operation of humidifier: Set humidistat
demand setting With the furnace off_ the so{enoid vatve should be
dosed. Start the fumace_ the sotenoid valve shoutd open when the
bIower or burner circuit is energized, Check flaw of water through
distributor t_ugh and evaporator pad, The standard GA4299 (ORANGE)
orifice will supp|y approximateiy 435 GPH of water a_ a Jine water
pressure of 60 psL For low water pressures (20`40 psi) a larger (BLUE)
orifice GA4232 is available to provide the same flow. Leave humidistat
set at the recommendedi setting,