Installation Guide

Hard carrying case
Combination air-speed
temperature probe
(General P/N P4207SD)
2 GB SD memory card
User’s manual
Includes combination air speed-temperature probe
Displays air (wind) speed in meters/second, feet per minute, kilometers/hr, knots
(nautical miles per hour), or miles per hour
Displays temperature in °F or °C
Big (2.5 in. diagonal) front-panel green backlit LCD is easy to read
Displays maximum and minimum readings and holds any reading
Automatically logs measurements at sampling time settable from one second to one hour
Also supports manual data logging and changing of SD card storage location
Auto power off function
Optional Accessories:
9VDC adapter for 110V power supply
(General P/N AC1)
“K” Type thermocouples
General P/N TPK500 (-50° to 500°F)
General P/N TPK05 (-40° to 562°F)
General P/N TPK03 (-40° to 950°F)
SDRD1 - SD Card Reader
Included Accessories:
Features:
Specifications:
Embedded Microcontroller: Custom one-chip LSI device
Display Type: LCD with green backlight
Display Size: 2.05 x 1.5 in. (52 x 38mm)
Parameters Measured: Air speed, temperature
Measurement Range:
• For air speed: 0.4 to 30 m/sec, 1.4 to 126 km/hr,
0.9 to 78.3 mph, 0.8 to 68 knots,
79 to 6890 ft/min
• For temperature: 32° to 122°F (0° to 50°C)
Measurement Accuracy:
• For air speed: ± (2% + 0.2 m/sec), ± (2% + 0.8 km/hr),
± (2% + 0.4 mph), ± (2% + 0.4 knots),
± (2% + 40 ft/min)
• For temperature: ± 1.5°F (± 0.8°C)
Measurement Resolution:
• For air speed: 0.1 m/sec, 0.1 km/hr, 0.1 mph, 0.1 knots,
1.0 ft/min
• For temperature: 0.1°F or C
Data Logging Sampling Time:
1 second to 1 hour
Settable Parameters: Date, time, auto power off, beep
sound, sampling time, decimal point or comma decimal
division, temperature unit, air speed unit, optional
thermocouple type (K or J)
Storable/Recallable Readings: Maximum, minimum
SD Card Capacity: 1GB to 16GB
Operating Temperature: 32° to 122°F (0° to 50°C)
Operating Relative Humidity: 0 to 85%
Power Consumption
• 15 mADC (normal operation, with backlight off
and SD card not saving data)
• 36 mADC with backlight on and card saving data
• 48 mADC with backlight on and card saving data
Dimensions of Instrument:
7.99 x 2.99 x 1.50 in. (203 x 76 x 38mm)
Weight of Instrument: 1.13 lb. (515g)
Diameter of Probe Head: 2.83 in. (72mm)
Power Source:
Six “AA” batteries or optional 9-VDC AC adapter