Installation Guide

Soft carrying case
Temperature-humidity probe
2 GB SD memory card
User’s manual
Optional Accessories:
Hard carrying case
9VDC adapter for 110V power supply
(General P/N AC1)
• “K” Type thermocouples:
General P/N TPK500 (-50
° to 500°F)
General P/N TPK05 (-40
° to 562°F)
General P/N TPK03 (-40
° to 950°F)
SDRD1 - SD Card Reader
Included Accessories:
Specifications:
Embedded Microcontroller: Custom one-chip LSI device
Display Type: LCD with green backlight
Display Size: 2.05 x 1.5 in. (52 x 38mm)
Parameters Measured: Temperature, relative humidity
(R.H.), dew point,
wet-bulb temperature
Measurement Range:
• For temperature: 32° to 122°F (0° to 50°C)
• For R.H.: 5 to 95%
• For dew point: -13.5
° to 120.1°F (-25.3° to 48.9°C)
• For wet-bulb temperature: -6.9
° to 122°F
(-21.6
° to 50°C)
Measurement Accuracy:
• ± 1.5°F (± 0.8°C) for temperature
• Sum of temperature and humidity accuracies for dew
point and wet-bulb temperature
Measurement Resolution:
• 0.1° (F or C) for temperature and humidity
Data Logging Sampling Time: 1 second to 1 hour
Settable Parameters: Date, time, auto power off, beep
sound, sampling time, decimal point
or comma decimal division,
temperature unit
Storable/Recallable Readings: Maximum, minimum
SD Card Capacity: 1 GB to 16 GB
Operating Temperature: 32° to 122°F (0° to 50° C)
Operating Relative Humidity: 0 to 85%
Power Consumption::
• 3.5 mADC (normal operation, with backlight off and
SD card not saving data)
• 28 mADC with backlight on and card saving data
• 40 mADC with backlight on and card saving data
Dimensions of Meter:
6.97 x 2.68 x 1.77 in. (177 x 68 x 45mm)
Weight of Meter: 1.08 lb. (489g)
Power Source:
Six “AA” batteries or optional 9-VDC AC adapter
Humidity-Temperature Meter
with Excel-Formatted Data Logging SD Card
General Tools & Instruments
80 White Street, New York, NY 10013-3567
TEL: 212. 431. 6100 TOLL FREE: 800. 697. 8665
sales@generaltools.com www.generaltools.com
24
No. DTH3007SD
Four-function instrument measures temperature/humidity, dew point, wet-bulb
temperature and surface temperature
Big (2.5 in. diagonal) front-panel green backlit LCD is easy to read
Displays maximum and minimum readings and holds any reading
Automatically logs measurements at sampling time settable from one second to one hour
Also supports manual data logging and changing of SD card storage location
Auto power off function
Features: