User's Manual
7
with a camel’s hair brush. Carefully wipe the surface with a moist cotton swab
2、Keep clean; Avoid drop and wet; the housing could be cleaned with wet sponge.
C a u t i o n s
● Don’t drop and use the tool by force.
● Don’t disassemble the tool, (avoid causing trouble).
● Keep the tool dry and clean.
● Don’t place the tool with corrosive gas or objects.
● Avoid dust and water, which may stain the lens.
● Don’t clean the lens by any solvent.
● Don’t immerse the tool into water to avoid damage.
● In case of damage of tool by deterioration of battery.
● Remove the battery when not in use for an extended period of time.
Technical Specifications
Name ToolSmart Infrared Thermometer
Model
TS05
Measuring range
-40℃~580℃(-40℉~1076℉)
Response wavelength
8~14µm
Measuring precision
±2 (±3.6 ) or ±2% of reading℃ ℉ (when T>0℃
±3 (±5.4 ) or ±2% of reading, whichever is greater℃ ℉ (when T
≤0℃)
Repetition 1% of reading or 1℃
Response time
500mSec,95% response
Optical ratio(D:S) 12:1
Emissivity 0.95
Display resolution ±0.1℃
Laser wavelength
630~660nm
Power of laser <3mW
Laser class Class 3R
Laser switch √
Backlight switch √
Data hold √
Temperature units exchange √
Low battery indication √
Half light of the backlight No operation about 20 seconds by default
Auto turn off for tool No operation about 1 minutes by default
Bluetooth transfer function Can connect IOS (iPhone and iPad), Android and other
intelligent platform based on bluetooth 4.0
Power supply One 9V battery (6F22/6LR61)
Working current <50mA