Battery voltage Measurement ranges 0 to 9V, 0 to 1.5V
Measurement ±(0.8% of reading + 7 digits)
accuracy in
9V
position; ±(3% of
reading + 5 digits) in
1.5V
position
Max resolution 1mV
Safety rating CAT III 600V
NCV detection >110VAC
RMS
voltage & distance @ <1/4 in. (6mm)
Bluetooth range 33 ft. (10m)
Maximum input voltage 600VDC/AC
RMS
Fuse protection 400mV/600V fuse for jack;
10A/600V fuse for
A
jack
Sampling time 3X/sec
Display No. of digits 3-3/4
Maximum count 4000
Low battery indication threshold <6.7VDC
Operating temperature 32° to 104°F (0° to 40°C)
@<80%RH
Power source (1) “9V” battery (included)
Dimensions 5.8 x 2.9 x 2.0 in.
(148 x 74 x 50mm)
Weight (including battery) 8.2 oz. (232g)
Note: Accuracy values are stated for an operating temperature between
64° and 82°F (18° and 28°C) with RH<80%. Accuracies are lower outside
this range, in proportion to the actual operating temperature's distance
from the “sweet spot.”