User guide

With roll over
• Finally press ALERT to confirm and exit
When ambient RH reach the preset level, the
relevant arrow icon and the Humidity digit will
flash. Press any key to stop alarm and flashing.
Alarm beeps for 60 seconds and rests for
55 minutes, it repeats beeping when within the
range. Press any key to stop beeping.
5. TEMPERATURE TREND:
- 3 arrows each for indoor and outdoor temp, total 6
arrows
- Up, Steady, Down
- Power-up display STEADY
- If temp goes up for 1.0 degree higher, the icon
immediately indicates UP
- If temp stays within 1.0 degree for 450 samplings
(1 hr), icon indicates STEADY
- If temp goes down for 1.0 degree or more, the icon
immediately indicates DOWN
- When MAX or MIN temp is on screen, a press on
the CLEAR button will immediately clear the UP or
DOWN icon to STEADY
DTH850 Manual -FIN3-100907 10/9/07 12:06