VANE ANEMOMETER HUMIDITY/TEMP.
TABLE OF CONTENTS 1. FEATURES.................................................................1 2. SPECIFICATIONS.......................................................2 2-1 General Specifications.......................................... 2 2-2 Electrical Specifications........................................ 3 3. FRONT PANEL DESCRIPTION..................................... 5 3-1 Vane...................................................................5 3-2 Humidity/Temp. Sensor...............................
1. FEATURES * Anemometer, Humidity, Temperature meter, 4 in one, professional. * Anemometer unit : m/S, Km/h, FPM, mph, Knot. * Humidity with Dew point measurement * Temperature measurement with ℃, ℉ unit. * Vane anemometer, available for wind speed measurement, high reliability. * Fast response time for humidity measurement. * Two display can select the three mode ( function ) : Humidity/Temp., Humidity/Dew point, Anemometer/Temp.. * Bright LCD display.
2. SPECIFICATIONS 2-1 General Specifications Display Anemometer Unit LCD size : 1.1" X 0.8" (28 mm x 19 mm). m/S (meters per second) Km/h ( kilometers per hour ) FPM ( feet per minute ) mph ( miles per hour ) Knot ( nautical miles per hour ) Temp. unit ℃, ℉ Humidity unit %RH Dew point ℃, ℉ Circuit Custom one-chip of microprocessor LSI circuit. Sensor Anemometer Van probe with low friction Structure ball bearing design.
Power Supply Power Current Weight Dimension Accessories Included Optional Accessory DC 1.5 V battery ( UM4/AAA ) x 4 PCs, Approx. DC 5.2 mA 182 g/ 0.4 LB. @ Battery is included. 205 x 48 x 40 mm (8.1" x 1.9" x 1.6") Instruction manual......................1 PC Soft carrying case with sash ( 210 x 80 x 50 mm ), 2-2 Electrical Specifications (23± 5 ℃) Anemometer ( Air velocity ) Measurement Range m/S Km/h FPM mph Knot Resolution Accuracy 0.4 to 30.0 m/s 1.4 to 108.0 km/h 80 to 5910 ft/min 0.9 to 67.
Humidity / Dew point a. Humidity Range Resolution Accuracy b. Dew point ℃ ℉ 10 % to 95 % R.H. 0.1 % R.H. ≧70% RH ± (3% reading + 1% RH). < 70% RH - 3% RH. ± 3% RH. Range Resolution Range Resolution -25.3 ℃ to 48.9 ℃ 0.01 ℃ -13.5 ℉ to 120.1 ℉. 0.01 ℉ . Remark : * Dew Point display value is calculated from the Humidity/Temp. measurement automatically. * The Dew Point accuracy is sum accuracy value of Humidity & Temperature measurement..
3. FRONT PANEL DESCRIPTION Fig. 1 3-1 3-2 3-3 3-4 3-5 3-6 3-7 Vane Humidity/Temp.
4. MEASURING PROCEDURE 4-1 Mode ( Function ) selection 1) Turn on the meter by pressing the " Power Button " ( 3-3, Fig. 1 ) momentarily. * Pressing the " Power Button " ( 3-3, Fig. 1 ) momentarily again will turn off the meter. 2) The meter can select three kind mode ( function ) as : a. Humidity/Temp. b.Humidity/Dew point c. Anemometer/Temp. Pressing the " Mode Button " ( 3-5, Fig.
%RH 60.9 Value Flashing Value Flashing 25.9 ℃ * After the mode ( function ) is selected, it will be memorized into the memory circuit . If power off and on again will present the existing selection mode ( function ). 4-2 Unit selection 1) Turn on the meter by pressing the " Power Button " ( 3-3, Fig. 1 ) momentarily. * Pressing the " Power Button " ( 3-3, Fig. 1 ) momentarily again will turn off the meter. 2) Pressing the " Unit Button " ( 3-4, Fig.
Unit Flashing %RH 60.9 25.9 ℃ Unit Flashing The measuring unit for different mode ( function ) are : Anemometer unit Temp. unit Humidity unit Dew point m/S, Km/h, FPM, mph, Knot ℃, ℉ %RH ℃, ℉ * After the unit is selected, it will be memorized into the memory circuit. If power off and on again will present the existing selection unit. 4-3 Anemometer measurement 1) Turn on the meter by pressing the " Power Button " ( 3-3, Fig. 1 ) momentarily.
4-4 Humidity measurement 1) Turn on the meter by pressing the " Power Button " ( 3-3, Fig. 1 ) momentarily. 2)For the above 4-1 mode ( function ) selection, please set to : a. Humidity/Temp. ( Upper display show humidity value , lower display show Temp. value ) 4-5 Dew point measurement 1) Turn on the meter by pressing the " Power Button " ( 3-3, Fig. 1 ) momentarily. 2)For the above 4-1 mode ( function ) selection, please set to : b.
4-7 Data Record ( Max., Min. reading ) 1) The data record function records the maximum and minimum readings. Press the " REC Button " ( 3-5, Fig. 1 ) momentarily to start the Data Record function, shows " REC " on the display. 2) With the " REC " symbol on the display. a) Press the " REC Button " ( 3-5, Fig. 1 ) momentarily, the " REC MAX " symbol along with the maximum value will appear on the display. b)Press the " REC Button " ( 3-5, Fig.
4-8 Auto power off management 1) The instrument has built-in "Auto Power Shut-off " function in order to prolong battery life. The meter will switch off automatically if none of the buttons are pressed within 10 min. 2)To de-activate this feature, Select the memory record function during measurement, by pressing the " REC Button " ( 3-5, Fig. 1 ). 5. BATTERY REPLACEMENT * Replace the batteries when the left corner of the LCD displays the low battery icon " ", using 4 fresh 1.5 V ( UM4, AAA ) batteries.