UPM Model
Post Size
(sch = schedule, or
thickness of pipe
wall)
Max Pole
Height
above
concrete
Base
w/array
@ 45
tilt
Clearance
between
top of
concrete
and
lowest
point on
array @
45
tilt
Max Pole
Height
above
concrete
base
w/array
@ 60
tilt
Clearance
between
top of
concrete
and
lowest
point on
array @
60
tilt
Max Pole
Height
above
concrete
base
w/array
@ 90
tilt
See
Footnote 2
Clearance
between
top of
concrete
and
lowest
point on
array @
90
tilt
See
Footnote 2
UPM12XHD
Custom
8 Modules: 4
rails, 2 columns
of 4 panels
Standard stock
tee socket size
8”, optional
upgrade to 10”
available
No 8” sch 40
8” Sch 80 8 5/8” OD
10” sch 40 10 ¾” OD
10” sch 80 10 ¾” OD
15’ 3”
18’ 9”
21’
11’
14’ 6”
16’ 9”
12’ 5”
15’ 3”
20’
7’ 1”
9’ 11”
14’ 8”
10’ 8”
13’
20’
4’ 8”
6’ 7”
13’ 7”
UPM15X
12 Modules: 6
rails, 3 columns
of 4 panels
Standard stock
tee socket size
8”, optional
upgrade to 10”
available
No 8” sch 40
8” Sch 80 8 5/8” OD
10” sch 40 10 ¾” OD
10” sch 80 10 ¾” OD
11’ 9”
14’ 6”
21’
7’ 6”
10’ 3”
16’ 9”
9’ 6”
11’ 9”
18’ 3”
4’ 2”
6’ 5”
12’ 11”
8’ 3”
10’
15’ 8”
1’ 10”
3’ 7”
9’ 3”
UPM15X
10 Modules: 6
rails, 3 columns
of 3,4,3 panels
Standard stock
tee socket size
8”, optional
upgrade to 10”
available
No 8” sch 40
8” Sch 80 8 5/8” OD
10” sch 40 10 ¾” OD
10” sch 80 10 ¾” OD
12’ 3”
14’ 9”
21’
9’ 3”
11’ 9”
18’
9’ 9”
12’ 2”
18’ 9”
4’ 5”
6’ 10”
13’ 5”
8’ 6”
10’ 6”
16’ 3”
2’ 1”
4’ 1”
9’ 10”
UPM18X
15 Modules: 6
rails, 3 columns
of 5 panels
Standard stock
tee socket size
8”, optional
upgrade to 10”
available
No 8” sch 40
8” Sch 80 8 5/8” OD
10” sch 40 10 ¾” OD
10” sch 80 10 ¾” OD
9’ 3”
11’ 5”
17’ 9”
4’
6’ 2”
12’ 6”
7’ 6”
9’ 3”
14’ 3”
1’ 2”
2’ 10”
7’ 10”
See footnote 1
See footnote 1
12’ 3”
See footnote 1
See footnote 1
4’ 7”
UPM18X
12 Modules: 6
rails, 3 columns
of 4 panels
Standard stock
tee socket size
8”, optional
upgrade to 10”
available
No 8” sch 40
8” Sch 80 8 5/8” OD
10” sch 40 10 ¾” OD
10” sch 80 10 ¾” OD
10’
12’ 4”
19’ 3”
5’ 9”
8’ 1”
15’
8’ 2”
10’
15’ 6”
2’ 10”
4’ 8”
10’ 2”
7’
8’ 7”
13’ 3”
7”
2’ 2”
6’ 10”
Footnote 1: There is not adequate clearance for these arrays with this size pipe. Use heavier schedule
pipe or larger pipe diameter.
Footnote 2: For UPM12XHD, 12XHD Custom, 15X and 18X we do not recommend tilting past 65 without
using the optional 90 bracket kit. This kit fastens the array to the pole below the tee top which is the
safest and strongest possible attachment for the 90 vertical position. Most mounts do not need to be
tilted past 65 unless they are in far north latitudes or in areas with extreme snow loads.