object i
s active.
Alarm Sets the Audible Alarm for the SRVC
object. When an Audible Alarm is
selected, the selected alarm will play
anytime the scanner stops for activity
on the SRVC object while scanning.
None, Chirp, Hi-Lo, Alert,
Ring, 2-Chirp, Fast Hi-Lo,
DTMF#
Fav Yes or No When Yes, the SRVC object is a
member of the Favorites Scan List.
EXPERT BELOW
Modulation AM, FM, Auto Modulation setting for the SRVC
search. In most cases Auto will work
fine. Use AM to override and force
AM modulation, FM to force FM
modulation.
Atten On or Off When on, applies 20 dB of
attenuation to all hits received on the
SRVC search. Useful in areas where
interference from nearby strong
signals is present.
Delay On or Off Controls whether a Delay is used to
wait for reply traffic after a
transmission on the SRVC search.
Delay Time 1-200 Sets the amount of time (in 100
millisecond intervals) for the wait for
reply delay if Delay is On, e.g., 20=2
seconds.
Zeromatic On or Off When on, enhances the scanner's
ability to lock on to the actual center
frequency of a search hit instead of
an adjacent frequency.
Search Dir Up or Down Sets search direction used when
SRVC object is active.
Hit Count Numeric value Increments each time a transmission
is received on the SWPR object.
Global “Hit Counts” must be set to
ON. Press the Dflt softkey to reset to
0.
Page
82