User's Manual

Atten On or Off When on, applies 20 dB of attenuation to
all transmissions on the CONV channel.
Useful in areas where interference from
nearby strong signals is present.
Delay On or Off Controls whether a Delay is used to wait
for reply traffic after a transmission on the
CONV channel.
Delay Time 1-200 Sets the amount of time (in 100
millisecond intervals) for the wait for reply
delay if Delay is On, e.g., 20=2 seconds.
AudioBoost On or Off Applies a 6 dB boost to audio levels
when the object is active
Hit Count Numeric value Increments each time a transmission is
received on the SWPR object. Global “Hit
Counts” must be set to ON. Press the Dflt
softkey to reset to 0.
TGRP Menu Reference
The TGRP menu is used when creating new Trunking Talkgroup objects, or editing existing Trunking
Talkgroup objects. All menus are shown in the scanner's display as a three line window that can be scrolled
up or down to access the various different parameters. The active parameter is always the middle
parameter and is indicated by a flashing “:”. The entire TGRP menu is shown below:
TGRP Parameter Options Description
Scan Lists On or Off for Scan Lists
1-22
Sets membership in Scan Lists. Use <>
keys to scroll through Scan Lists. Use
SEL key to toggle Scan List
membership. A “*” next to the Scan List
number indicates that the object is
mapped to that Scan List.
TSYS New or previously
stored trunking system
object (TSYS)
To enter a new trunking system, use the
<> keys to scroll through the stored
systems until NEW appears, then press
SEL to enter the parameters for the new
TSYS. To use a trunking system that you
have previously entered, use the <>
keys to scroll to the desired system.