User's Manual

channel. Also accessed by pressing
FUNC L/OUT while the scanner is
stopped on the CONV object.
Priority On or Off Turns Priority Mode on or off for the
CONV object.
LED Mode Solid or Flash Controls whether the ALERT LED
flashes or remains on solid when the
ALERT LED is used.
LED Color 0-7 Sets LED color to 0-7 as defined in the
GLOB menu. By default, 0=LED Off,
1=Red, 2=Yellow, 3=Green, 4=Cyan,
5=Blue, 6=Magenta, 7=White.
Latch LED On or Off Normally the ALERT LED is active only
while the object is receiving a
transmission. When Latch is on, the
ALERT LED will remain lit after the
transmission is complete, unless
overridden by a subsequent object that is
also using the ALERT LED.
Backlight On, Off or Flash Controls whether the backlight should be
on, off or flashing while the object is
active.
Alarm None, Chirp, Hi-Lo,
Alert, Ring, 2-Chirp,
Fast Hi-Lo, DTMF#
Sets the Audible Alarm for the CONV
object. When an Audible Alarm is
selected, the selected alarm will play at
the beginning of each transmission on
the CONV object, or anytime the scanner
stops for activity on the CONV object
while scanning.
Fav Yes or No When Yes, the CONV object is a member
of the Favorites Scan List.
Skywarn Yes or No When Yes, the CONV object is a member
of the Skywarn Scan List.
EXPERT BELOW
Modulation AM, FM, NFM, Auto Modulation setting for the CONV
channel. In most cases Auto will work
fine. Use AM to override and force AM
modulation, FM to force FM modulation,
NFM to force narrow FM modulation.