User's Manual
When checked, the selected object is Locked Out and will not be
scanned. Locked Out status is not changed when the Main
Menuʼs Restore Skipped utility is used. Use the ▶/II/SEL key to
toggle Locked Out status.
Skipped
When checked, the selected object is Skipped and will not be
scanned. Skipped status is restored when the Main Menuʼs
Restore Skipped utility is used. Use the ▶/II/SEL or keys to
toggle Skipped status.
Priority
When checked, Priority is enabled for the selected object. When
enabled, Priority causes the scanner to check for activity more
frequently on objects with Priority enabled. Priority Mode must be
enabled from the Main Menu to use the Priority feature. Use the
▶/II/SEL or keys to toggle Priority status. Priority status is
indicated in the object displayʼs psD indicator. “p” indicates that
priority is not enabled for the object, and “P” indicates that priority
is enabled for the object.
Delay
Enables or disables delay for the selected object. When delay is
enabled, the EZ Scan-SD waits for two seconds after a
transmission to receive reply traffic before resuming scanning.
Attenuate
When checked, attenuation is enabled for the selected object.
Attenuation may help reduce interference from strong local
transmitters. Use the ▶/II/SEL or keys to toggle Attenuate
status. Attenuate is not available in the Object Menu for trunked
talkgroups.
Alarm
Defines an audible alarm that is heard whenever there is activity
on the object. Use the or keys to select the desired alarm
sound.
Light
Defines backlight behavior for the selected object. Use the or
keys to select the desired light behavior. Options are Leave
(use default backlight settings), On (turn the backlight on) or
Flash (flash the backlight according to the Flash Pattern setting).
Flash Pattern, On Time, Off Time
GENERAL RESEARCH OF ELECTRONICS, INC. PROPRIETARY AND CONFIDENTIAL INFORMATION
EZ Scan-SD Preliminary User Manual" Page 42