TROUBLESHOOTING
The pump does not produce any noise at start-up:
The pump is not primed and is running dry
There is no water in the inlet line
The valves are blocked
The delivery line is closed and does not allow the air in the pump to be discharged
The pump pulses irregularly (knocking):
Air suction
Insufficient feeding
Bends, elbows, fittings along the suction line obstruct the fluid’s passage
The inlet filter is dirty or too small
The booster pump, where provided, supplies insufficient pressure or flow rate
The pump is not primed due to insufficient head or the delivery line is closed during priming
The pump is not primed due to valve seizing
Worn valves
Worn pressure packings
Incorrect operation of the pressure adjustment valve
Transmission problems
The pump does not deliver the rated flow / is noisy:
Insufficient feeding (see the causes listed above)
RPM are less than the rated flow
Excessive amount of water by-passed by the pressure adjustment valve
Worn valves
Leakage from the pressure packings
Cavitation due to:
1) Wrong sizing of the suction hose/
undersized diameters
2) Insufficient flow rate
3) High water temperature
Insufficient pump pressure:
The nozzle (or has become)too large
Insufficient RPM
Leakage from the pressure packings
Incorrect operation of the pressure adjustment valve
Worn valves
Overheated pump:
The pump is overloaded (pressure or RPM exceed the rated values)
Oil level is too low, or the oil is not of a suitable type, indicated in Chapter 7 (see paragraph 7.4)
Incorrect alignment of the joint or pulleys
Excessive inclination of the pump during operation
Pump vibrations or knocking:
Air suction
Incorrect operation of the pressure adjustment valve
Valve malfunction
Irregular drive transmission motion